ハイブリッド電気自動車駆動系における直流リンク電圧制御系の外乱の周波数帯域を考慮した設計法

Translated title of the contribution: Design method considering the frequency band of the disturbance in the DC link voltage control system of hybrid electric vehicle driving systems

Jongwon Heo*, Keiichiro Kondo

*Corresponding author for this work

Research output: Contribution to journalArticlepeer-review

1 Citation (Scopus)

Abstract

DC link voltage variable systems with DC/DC converter are used in hybrid electric vehicles for improving the power of the system by boosting the DC link voltage. Voltage feedback control using only proportional compensator has been proposed as a control method for the DC/DC converter. The control system can be easily designed, but there is a possibility that a steady-state error occurs in the DC link voltage. In this paper, a proportional integral compensator is proposed to eliminate the steady-state error of the DC link voltage in DC link voltage feedback controllers. In addition, when designing the gain of the compensator, the frequency band of the disturbance is considered. The proposed method is verified through experiments on the downsizing model.

Translated title of the contributionDesign method considering the frequency band of the disturbance in the DC link voltage control system of hybrid electric vehicle driving systems
Original languageJapanese
Pages (from-to)699-707
Number of pages9
Journalieej transactions on industry applications
Volume139
Issue number8
DOIs
Publication statusPublished - 2019 Jan 1

ASJC Scopus subject areas

  • Industrial and Manufacturing Engineering
  • Electrical and Electronic Engineering