TY - JOUR
T1 - A compact and high sensitivity positron detector using dual-layer thin GSO scintillators for a small animal PET blood sampling system
AU - Yamamoto, Seiichi
AU - Imaizumi, Masao
AU - Shimosegawa, Eku
AU - Kanai, Yasukazu
AU - Sakamoto, Yusuke
AU - Minato, Kotaro
AU - Shimizu, Keiji
AU - Senda, Michio
AU - Hatazawa, Jun
PY - 2010
Y1 - 2010
N2 - For quantitative measurements of small animals such as mice or rats, a compact and high sensitivity continuous blood sampling detector is required because their blood sampling volume is limited. For this purpose we have developed and tested a new positron detector. The positron detector uses a pair of dual-layer thin gadolinium orthosilicate (GSO) scintillators with different decay times. The front layer detects the positron and the background gamma photons, and the back layer detects the background gamma photons. By subtracting the count rate of the latter from that of the former, the count rate of the positrons can be estimated. The GSO for the front layer has a Ce concentration of 1.5 mol% (decay time of 35 ns), and that for the back layer has a Ce concentration of 0.5 mol% (decay time of 60 ns). By using the pulse shape analysis, the count rate of these two GSOs can be discriminated. The thickness is 0.5 mm, which is thick enough to detect positrons while minimizing the detection of the background gamma photons. These two types of thin GSOs were optically coupled to each other and connected to a metal photomultiplier tube (PMT) through triangular light guides. The signal from the PMT was digitized by 100 MHz free-running A-D converters in the data acquisition system and digitally integrated at two different integration times for the pulse shape analysis. We obtained good separation of the pulse shape distributions of these two GSOs. The energy threshold level was decreased to 80 keV, increasing the sensitivity of the detector. The sensitivity of a small diameter plastic tube was 8.6% and 24% for the F-18 and C-11 positrons, respectively. The count rate performance was linear up to ∼50 kcps. The background counts from the gamma photons could be precisely corrected. The time-activity curve (TAC) of the rat artery blood was successfully obtained and showed a good correlation with that measured using a well counter. With these results, we confirmed that the developed blood sampling detector is promising for quantitative measurement for an animal positron emission tomography system.
AB - For quantitative measurements of small animals such as mice or rats, a compact and high sensitivity continuous blood sampling detector is required because their blood sampling volume is limited. For this purpose we have developed and tested a new positron detector. The positron detector uses a pair of dual-layer thin gadolinium orthosilicate (GSO) scintillators with different decay times. The front layer detects the positron and the background gamma photons, and the back layer detects the background gamma photons. By subtracting the count rate of the latter from that of the former, the count rate of the positrons can be estimated. The GSO for the front layer has a Ce concentration of 1.5 mol% (decay time of 35 ns), and that for the back layer has a Ce concentration of 0.5 mol% (decay time of 60 ns). By using the pulse shape analysis, the count rate of these two GSOs can be discriminated. The thickness is 0.5 mm, which is thick enough to detect positrons while minimizing the detection of the background gamma photons. These two types of thin GSOs were optically coupled to each other and connected to a metal photomultiplier tube (PMT) through triangular light guides. The signal from the PMT was digitized by 100 MHz free-running A-D converters in the data acquisition system and digitally integrated at two different integration times for the pulse shape analysis. We obtained good separation of the pulse shape distributions of these two GSOs. The energy threshold level was decreased to 80 keV, increasing the sensitivity of the detector. The sensitivity of a small diameter plastic tube was 8.6% and 24% for the F-18 and C-11 positrons, respectively. The count rate performance was linear up to ∼50 kcps. The background counts from the gamma photons could be precisely corrected. The time-activity curve (TAC) of the rat artery blood was successfully obtained and showed a good correlation with that measured using a well counter. With these results, we confirmed that the developed blood sampling detector is promising for quantitative measurement for an animal positron emission tomography system.
UR - http://www.scopus.com/inward/record.url?scp=77953836760&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=77953836760&partnerID=8YFLogxK
U2 - 10.1088/0031-9155/55/13/016
DO - 10.1088/0031-9155/55/13/016
M3 - Article
C2 - 20551500
AN - SCOPUS:77953836760
SN - 0031-9155
VL - 55
SP - 3813
EP - 3826
JO - Physics in Medicine and Biology
JF - Physics in Medicine and Biology
IS - 13
ER -