T1 - A high-resolution X-ray microscope system for performance evaluation of scintillator plates
AU - Yamamoto, Seiichi
AU - Yoshino, Masao
AU - Kamada, Kei
AU - Yajima, Ryuga
AU - Yoshikawa, Akira
AU - Sagisaka, Mayu
AU - Kataoka, Jun
N1 - Publisher Copyright:
© 2022 IOP Publishing Ltd and Sissa Medialab.
PY - 2022/9/1
Y1 - 2022/9/1
N2 - In the development of new scintillators for X-ray imaging, a high-resolution and highly efficient system is required to evaluate the performance of the scintillator plates. For this purpose, we developed a high-resolution X-ray microscope system. The developed compact X-ray microscope system is based on a magnifying unit and a cooled charge-coupled device (CCD) camera, combined with a small industrial X-ray irradiation system. Using this system, we carried out imaging of three scintillator plates and evaluated their spatial resolution. Each scintillator plates was set in front of the lens of the objective, X-rays were irradiated to the scintillator plates, and transmission images of masks were acquired. The measured spatial resolution of the scintillator plates varied from 16 μm to 30 μm, depending on the type of scintillator plate. The focus size of the X-ray tube had an almost negligible effect on the spatial resolution of the images for the evaluated scintillator plates.
AB - In the development of new scintillators for X-ray imaging, a high-resolution and highly efficient system is required to evaluate the performance of the scintillator plates. For this purpose, we developed a high-resolution X-ray microscope system. The developed compact X-ray microscope system is based on a magnifying unit and a cooled charge-coupled device (CCD) camera, combined with a small industrial X-ray irradiation system. Using this system, we carried out imaging of three scintillator plates and evaluated their spatial resolution. Each scintillator plates was set in front of the lens of the objective, X-rays were irradiated to the scintillator plates, and transmission images of masks were acquired. The measured spatial resolution of the scintillator plates varied from 16 μm to 30 μm, depending on the type of scintillator plate. The focus size of the X-ray tube had an almost negligible effect on the spatial resolution of the images for the evaluated scintillator plates.
KW - Scintillators and scintillating fibres and light guides
KW - Scintillators, scintillation and light emission processes (solid, gas and liquid scintillators)
KW - X-ray detectors
KW - X-ray radiography and digital radiography (DR)
UR - http://www.scopus.com/inward/record.url?scp=85139760921&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=85139760921&partnerID=8YFLogxK
U2 - 10.1088/1748-0221/17/09/T09012
DO - 10.1088/1748-0221/17/09/T09012
M3 - Article
AN - SCOPUS:85139760921
SN - 1748-0221
VL - 17
JO - Journal of Instrumentation
JF - Journal of Instrumentation
IS - 9
M1 - T09012
ER -