TY - GEN
T1 - A newly developed stereotactic robot with detachable drive for neurosurgery
AU - Masamune, Ken
AU - Ji, L. H.
AU - Suzuki, Makoto
AU - Dohi, Takeyoshi
AU - Iseki, Hiroshi
AU - Takakura, Kintomo
PY - 1998
Y1 - 1998
N2 - This paper describes the development of a needle insertion manipulator for stereotactic neurosurgery. This robot fulfils the requirements of having both a safe mechanical design and the capacity for being sterilized. Many kinds of robots are examined in neurosurgery. Their purpose is the precise positioning of surgical instruments such as biopsy needles, electrodes etc. Some are already available commercially and have been proven useful in the operating theatre. However, their clinical application is limited by specific problems including cost, safety, positioning requirements, maintenance requirements. The main problems have been with the safety of the mechanical design and difficulties with sterilization and disinfecting pre-and post operatively. The manipulator described in this report achieves mechanical safety and has the capacity for cover-sheet-free sterilization. The manipulator has three major components: the main mechanical component (with 6 degrees of freedom), the torque transmission component, and the electric motor, which cannot be sterilized. The electrical parts are detachable. Using this mechanism, we can clearly separate the surgical area from the mechatronics components. In this paper, the basic design and the prototype development and testing are described.
AB - This paper describes the development of a needle insertion manipulator for stereotactic neurosurgery. This robot fulfils the requirements of having both a safe mechanical design and the capacity for being sterilized. Many kinds of robots are examined in neurosurgery. Their purpose is the precise positioning of surgical instruments such as biopsy needles, electrodes etc. Some are already available commercially and have been proven useful in the operating theatre. However, their clinical application is limited by specific problems including cost, safety, positioning requirements, maintenance requirements. The main problems have been with the safety of the mechanical design and difficulties with sterilization and disinfecting pre-and post operatively. The manipulator described in this report achieves mechanical safety and has the capacity for cover-sheet-free sterilization. The manipulator has three major components: the main mechanical component (with 6 degrees of freedom), the torque transmission component, and the electric motor, which cannot be sterilized. The electrical parts are detachable. Using this mechanism, we can clearly separate the surgical area from the mechatronics components. In this paper, the basic design and the prototype development and testing are described.
UR - http://www.scopus.com/inward/record.url?scp=84947764897&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=84947764897&partnerID=8YFLogxK
M3 - Conference contribution
AN - SCOPUS:84947764897
SN - 3540651365
SN - 9783540651369
VL - 1496
T3 - Lecture Notes in Computer Science (including subseries Lecture Notes in Artificial Intelligence and Lecture Notes in Bioinformatics)
SP - 215
EP - 222
BT - Lecture Notes in Computer Science (including subseries Lecture Notes in Artificial Intelligence and Lecture Notes in Bioinformatics)
PB - Springer Verlag
T2 - 1st International Conference on Medical Image Computing and Computer-Assisted Intervention, MICCAI 1998
Y2 - 11 October 1998 through 13 October 1998
ER -