TY - JOUR
T1 - Assessing physical activity and sedentary behavior under free-living conditions
T2 - Comparison of active style pro HJA-350IT and actigraphtm GT3X+
AU - Yano, Shohei
AU - Koohsari, Mohammad Javad
AU - Shibata, Ai
AU - Ishii, Kaori
AU - Mavoa, Suzanne
AU - Oka, Koichiro
N1 - Publisher Copyright:
© 2019 by the authors. Licensee MDPI, Basel, Switzerland.
PY - 2019/9
Y1 - 2019/9
N2 - Various accelerometers have been used in research measuring physical activity (PA) and sedentary behavior (SB). This study compared two triaxial accelerometers-Active style Pro (ASP) and ActiGraph (AG)-in measuring PA and SB during work and nonwork days in free-living conditions. A total of 50 working participants simultaneously wore these two accelerometers on one work day and one nonwork day. The difference and agreement between the ASP and AG were analyzed using paired t-tests, Bland-Altman plots, and intraclass coefficients, respectively. Correction factors were provided by linear regression analysis. The agreement in intraclass coefficients was high among all PA intensities between ASP and AG. SB in the AG vertical axis was approximately 103 min greater than ASP. Regarding moderate-to-vigorous-intensity PA (MVPA), ASP had the greatest amount, followed by AG. There were significant differences in all variables among these devices across all day classifications, except for SB between ASP and AG vector magnitude. The correction factors decreased the differences of SB and MVPA. PA time differed significantly between ASP and AG. However, SB and MVPA differences between these two devices can be decreased using correction factors, which are useful methods for public health researchers.
AB - Various accelerometers have been used in research measuring physical activity (PA) and sedentary behavior (SB). This study compared two triaxial accelerometers-Active style Pro (ASP) and ActiGraph (AG)-in measuring PA and SB during work and nonwork days in free-living conditions. A total of 50 working participants simultaneously wore these two accelerometers on one work day and one nonwork day. The difference and agreement between the ASP and AG were analyzed using paired t-tests, Bland-Altman plots, and intraclass coefficients, respectively. Correction factors were provided by linear regression analysis. The agreement in intraclass coefficients was high among all PA intensities between ASP and AG. SB in the AG vertical axis was approximately 103 min greater than ASP. Regarding moderate-to-vigorous-intensity PA (MVPA), ASP had the greatest amount, followed by AG. There were significant differences in all variables among these devices across all day classifications, except for SB between ASP and AG vector magnitude. The correction factors decreased the differences of SB and MVPA. PA time differed significantly between ASP and AG. However, SB and MVPA differences between these two devices can be decreased using correction factors, which are useful methods for public health researchers.
KW - Accelerometers
KW - Accelerometry
KW - Activity monitors
KW - Objective assessment
KW - Sitting time
UR - http://www.scopus.com/inward/record.url?scp=85071615231&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=85071615231&partnerID=8YFLogxK
U2 - 10.3390/ijerph16173065
DO - 10.3390/ijerph16173065
M3 - Article
C2 - 31450754
AN - SCOPUS:85071615231
SN - 1661-7827
VL - 16
JO - International journal of environmental research and public health
JF - International journal of environmental research and public health
IS - 17
M1 - 3065
ER -