TY - JOUR
T1 - Association between contraction-induced increases in elbow flexor muscle thickness and distal biceps brachii tendon moment arm depends on the muscle thickness measurement site
AU - Akagi, Ryota
AU - Iwanuma, Soichiro
AU - Hashizume, Satoru
AU - Kanehisa, Hiroaki
AU - Yanai, Toshimasa
AU - Kawakami, Yasuo
PY - 2014/2
Y1 - 2014/2
N2 - The purpose of this study was to investigate how the contraction-induced increase in distal biceps brachii tendon moment arm is related to that in elbow flexor muscle thickness, with a specific emphasis on the influence of the site-related differences in muscle thickness. The moment arm and muscle thickness were determined from sagittal and cross-sectional images, respectively, of the right arm obtained by magnetic resonance imaging of nine young men. The muscle thickness was measured at levels from the reference site (60% of the upper arm length from the acromial process of the scapula to the lateral epicondyle of the humerus) to 60 mm distal to it (every 10 mm; 7 measurement sites). At 80° of elbow flexion, the moment arm and muscle thickness were determined at rest and during 60% of maximal voluntary contraction (60%MVC) of isometric elbow flexion. Only the relative change from rest to 60%MVC in muscle thickness at the level 60 mm distal to the reference site correlated significantly with that of the moment arm. This result indicates that the contraction-induced increase in distal biceps brachii tendon moment arm is related to that in elbow flexor muscle thickness near the corresponding muscle-tendon junction.
AB - The purpose of this study was to investigate how the contraction-induced increase in distal biceps brachii tendon moment arm is related to that in elbow flexor muscle thickness, with a specific emphasis on the influence of the site-related differences in muscle thickness. The moment arm and muscle thickness were determined from sagittal and cross-sectional images, respectively, of the right arm obtained by magnetic resonance imaging of nine young men. The muscle thickness was measured at levels from the reference site (60% of the upper arm length from the acromial process of the scapula to the lateral epicondyle of the humerus) to 60 mm distal to it (every 10 mm; 7 measurement sites). At 80° of elbow flexion, the moment arm and muscle thickness were determined at rest and during 60% of maximal voluntary contraction (60%MVC) of isometric elbow flexion. Only the relative change from rest to 60%MVC in muscle thickness at the level 60 mm distal to the reference site correlated significantly with that of the moment arm. This result indicates that the contraction-induced increase in distal biceps brachii tendon moment arm is related to that in elbow flexor muscle thickness near the corresponding muscle-tendon junction.
KW - Center of rotation method
KW - Magnetic resonance imaging
KW - Submaximal isometric contraction
UR - http://www.scopus.com/inward/record.url?scp=84897411182&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=84897411182&partnerID=8YFLogxK
U2 - 10.1123/jab.2012-0145
DO - 10.1123/jab.2012-0145
M3 - Article
C2 - 24676520
AN - SCOPUS:84897411182
SN - 1065-8483
VL - 30
SP - 134
EP - 139
JO - Journal of Applied Biomechanics
JF - Journal of Applied Biomechanics
IS - 1
ER -