TY - JOUR
T1 - Comparison of multiple prompt γ-ray analysis and prompt γ-ray analysis for the elemental analysis of geological and cosmochemical samples.
AU - Islam, Mohammad Amirul
AU - Ebihara, Mitsuru
AU - Toh, Yosuke
AU - Harada, Hideo
PY - 2011/10/1
Y1 - 2011/10/1
N2 - Multiple prompt γ-ray analysis (MPGA) and conventional neutron-induced prompt γ-ray analysis (PGA) are nondestructive analytical methods for bulk chemical compositions, and their analytical capabilities were compared for elemental analyses of geological and cosmochemical samples. Detection sensitivities of PGA are often restricted by poor signal-to-noise ratios and interferences from different origins. MPGA can substantially reduce the background level, especially for hydrogenous samples, relative to PGA, which opens up a possibility to use lower energy prompt γ-rays of some trace elements. Although it is one of the major constituent elements of rock samples, Mg is hard to be determined by PGA. With MPGA, Mg contents could be determined with reasonable consistency with their corresponding recommended values in geological and cosmochemical samples by carefully selecting suitable coincident prompt γ-ray energy pairs without interference correction. MPGA was applied to a hydrogenous meteorite, Ivuna, which contains H at 2% mass level. MPGA detection limits for most of the elements studied can be reduced up to 1 order of magnitude when compared with PGA detection limits under the present experimental conditions.
AB - Multiple prompt γ-ray analysis (MPGA) and conventional neutron-induced prompt γ-ray analysis (PGA) are nondestructive analytical methods for bulk chemical compositions, and their analytical capabilities were compared for elemental analyses of geological and cosmochemical samples. Detection sensitivities of PGA are often restricted by poor signal-to-noise ratios and interferences from different origins. MPGA can substantially reduce the background level, especially for hydrogenous samples, relative to PGA, which opens up a possibility to use lower energy prompt γ-rays of some trace elements. Although it is one of the major constituent elements of rock samples, Mg is hard to be determined by PGA. With MPGA, Mg contents could be determined with reasonable consistency with their corresponding recommended values in geological and cosmochemical samples by carefully selecting suitable coincident prompt γ-ray energy pairs without interference correction. MPGA was applied to a hydrogenous meteorite, Ivuna, which contains H at 2% mass level. MPGA detection limits for most of the elements studied can be reduced up to 1 order of magnitude when compared with PGA detection limits under the present experimental conditions.
UR - http://www.scopus.com/inward/record.url?scp=84856266069&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=84856266069&partnerID=8YFLogxK
U2 - 10.1021/ac201706g
DO - 10.1021/ac201706g
M3 - Article
C2 - 21823645
AN - SCOPUS:84856266069
SN - 0003-2700
VL - 83
SP - 7486
EP - 7491
JO - Analytical Chemistry
JF - Analytical Chemistry
IS - 19
ER -