TY - JOUR
T1 - Contribution of multiple electron trajectories to high-harmonic generation in the few-cycle regime
AU - Naumov, A. Yu
AU - Villeneuve, D. M.
AU - Niikura, Hiromichi
N1 - Publisher Copyright:
© 2015 American Physical Society.
PY - 2015/6/26
Y1 - 2015/6/26
N2 - We use a few-cycle, carrier-envelope-phase (CEP) stabilized laser system to generate high-harmonic emission in argon, neon, and carbon dioxide. The high-harmonic spectra consist of discrete harmonic orders whose positions shift as a function of the CEP. Near the cutoff harmonic, the peaks are separated by two photon orders, and can correspond to either even or odd harmonics of the driving laser frequency, depending on the value of the CEP. In the plateau region, harmonic orders are separated by only one photon order. We develop a simple model which predicts the observed behavior. We use the observed dependence of the harmonic peaks as a function of CEP as a method to measure the statistical CEP fluctuations of the laser system. The measured rms fluctuation of 0.17 radians agrees with optical measurements. The high-harmonic approach to measuring CEP stability has the advantage that it is less sensitive to laser intensity fluctuations than are optical methods.
AB - We use a few-cycle, carrier-envelope-phase (CEP) stabilized laser system to generate high-harmonic emission in argon, neon, and carbon dioxide. The high-harmonic spectra consist of discrete harmonic orders whose positions shift as a function of the CEP. Near the cutoff harmonic, the peaks are separated by two photon orders, and can correspond to either even or odd harmonics of the driving laser frequency, depending on the value of the CEP. In the plateau region, harmonic orders are separated by only one photon order. We develop a simple model which predicts the observed behavior. We use the observed dependence of the harmonic peaks as a function of CEP as a method to measure the statistical CEP fluctuations of the laser system. The measured rms fluctuation of 0.17 radians agrees with optical measurements. The high-harmonic approach to measuring CEP stability has the advantage that it is less sensitive to laser intensity fluctuations than are optical methods.
UR - http://www.scopus.com/inward/record.url?scp=84936971328&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=84936971328&partnerID=8YFLogxK
U2 - 10.1103/PhysRevA.91.063421
DO - 10.1103/PhysRevA.91.063421
M3 - Article
AN - SCOPUS:84936971328
SN - 1050-2947
VL - 91
JO - Physical Review A - Atomic, Molecular, and Optical Physics
JF - Physical Review A - Atomic, Molecular, and Optical Physics
IS - 6
M1 - 063421
ER -