T1 - Development of an ADL and Neuro-Rehabilitation assistance apparatus for upper limbs and evaluation of muscle and cerebral activity
AU - Tanaka, Eiichirou
AU - Saegusa, Shozo
AU - Iwasaki, Yasuo
AU - Yuge, Louis
N1 - Publisher Copyright:
© 2014 TSI Press.
PY - 2014/10/24
Y1 - 2014/10/24
N2 - An assistance apparatus for upper limbs for patients who can control their finger but they cannot lift up their arms themselves, for example myopathy and hemiplegic patients, was developed. The mechanism of assistance is utilizes the differential gears to lose the weight and volume of the mechanical arm. That enabled us to configure three motors to drive two DOFs (Degrees of freedom) for the shoulder and one DOF for the elbow around the root of the mechanical arm. This arm has two support trays, for wrist and upper arm. Furthermore, to realize other ADL (activities of daily living) motions (for instance, eating, writing, putting on making up, wiping his/her face, and so on) themselves, we proposed to control the device using the targeted posture map for the mechanical arm. To be able to choose the appropriate input for each patient, various input interfaces, for example, joy-stick, push buttons, sensor glove using bending sensors, and so on, are equipped. Generally, even though a human behaves an atonic motion, the maximum voluntary contraction (%MVC) outputs at least from 5 to 10 %. The usage of this apparatus is to move the user's upper limbs with dependence completely, and the purpose of this apparatus is to decrease the value of %MVC up to approximately 10 %. Therefore, in this paper, the muscles of the user were evaluated with the ratio of %MVC. To confirm the effectiveness of assistance ability, we measured muscle activity while using the device, and compared the %MVC data between using the device or not. As a result, the activity decreased up to 80%, and the effectiveness of this device could be confirmed. Furthermore, to expand the usage of this apparatus to encompass Neuro-Rehabilitation as well, we measured cerebral activity while using the device for rehabilitation with a near-infrared spectroscopy (NIRS). Then we compared the data from using the device or not, and input motion from a third person. By using this device, the cerebral activity decreased especially when the target motion was complex. However, when the subject input the motion themselves, the cerebral activity increased more than when the data is input by a third person, especially, when the target motion was complex. Therefore, for use in Neuro-Rehabilitation, we found it is important the subject input the target motion him/herself. Finally, the influence of the cerebral activity according to the difference of the input devices was measured. As a result, these kinds of input devices have to be selected according to the purpose of the user.
AB - An assistance apparatus for upper limbs for patients who can control their finger but they cannot lift up their arms themselves, for example myopathy and hemiplegic patients, was developed. The mechanism of assistance is utilizes the differential gears to lose the weight and volume of the mechanical arm. That enabled us to configure three motors to drive two DOFs (Degrees of freedom) for the shoulder and one DOF for the elbow around the root of the mechanical arm. This arm has two support trays, for wrist and upper arm. Furthermore, to realize other ADL (activities of daily living) motions (for instance, eating, writing, putting on making up, wiping his/her face, and so on) themselves, we proposed to control the device using the targeted posture map for the mechanical arm. To be able to choose the appropriate input for each patient, various input interfaces, for example, joy-stick, push buttons, sensor glove using bending sensors, and so on, are equipped. Generally, even though a human behaves an atonic motion, the maximum voluntary contraction (%MVC) outputs at least from 5 to 10 %. The usage of this apparatus is to move the user's upper limbs with dependence completely, and the purpose of this apparatus is to decrease the value of %MVC up to approximately 10 %. Therefore, in this paper, the muscles of the user were evaluated with the ratio of %MVC. To confirm the effectiveness of assistance ability, we measured muscle activity while using the device, and compared the %MVC data between using the device or not. As a result, the activity decreased up to 80%, and the effectiveness of this device could be confirmed. Furthermore, to expand the usage of this apparatus to encompass Neuro-Rehabilitation as well, we measured cerebral activity while using the device for rehabilitation with a near-infrared spectroscopy (NIRS). Then we compared the data from using the device or not, and input motion from a third person. By using this device, the cerebral activity decreased especially when the target motion was complex. However, when the subject input the motion themselves, the cerebral activity increased more than when the data is input by a third person, especially, when the target motion was complex. Therefore, for use in Neuro-Rehabilitation, we found it is important the subject input the target motion him/herself. Finally, the influence of the cerebral activity according to the difference of the input devices was measured. As a result, these kinds of input devices have to be selected according to the purpose of the user.
KW - ADL and Neuro-Rehabilitation Assistance
KW - Cerebral Activity
KW - Muscle Activity
UR - http://www.scopus.com/inward/record.url?scp=84908879540&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=84908879540&partnerID=8YFLogxK
U2 - 10.1109/WAC.2014.6936037
DO - 10.1109/WAC.2014.6936037
M3 - Conference contribution
AN - SCOPUS:84908879540
T3 - World Automation Congress Proceedings
SP - 543
EP - 548
BT - World Automation Congress Proceedings
PB - IEEE Computer Society
T2 - 2014 World Automation Congress, WAC 2014
Y2 - 3 August 2014 through 7 August 2014
ER -