T1 - Efficient Operation of Heat Source using High-temperature Chilled Water in an Advanced Office Building
AU - Suzuki, Yuya
AU - Imazu, Misa
AU - Shinoda, Jun
AU - Furukawa, Ryoya
AU - Araki, Yumiko
AU - Tanabe, Shin Ichi
AU - Fujino, Kenji
AU - Hatori, Daisuke
AU - Hirasuga, Nobuhiro
AU - Kato, Shun
AU - Sasahara, Shiori
AU - Iwata, Hiroki
N1 - Publisher Copyright:
© The Authors, published by EDP Sciences. This is an open access article distributed under the terms of the Creative Commons Attribution License 4.0
PY - 2019/8/13
Y1 - 2019/8/13
N2 - In recent years, energy conservation has become a major focus in the industrial sector. Many office buildings in Japan achieve energy savings by introducing highly efficient equipment and systems, such as high-temperature cooling water (14 °C), which increases heat source efficiency. However, such equipment requires adjustments to increase operational efficiency. In this case study, the efficiency of equipment using high-temperature cooling water was further improved through operation control optimization. The energy efficiency before and after the improvement was compared. The target building has chilled and hot water supplied to each floor from district heating and high-temperature chilled water supplied from cooling chillers on the rooftop. The energy consumption of two floors was evaluated: a subjective floor with equipment using high-temperature cooling water installed, and a common floor with a conventional system. After on-site verification, changes were made to the operation control of the cooling towers, condenser pumps, primary pumps, secondary pumps, and air handling units. As a result, the coefficient of performance of the water-cooled chiller and the whole system improved by 0.40 and 0.45, respectively. The flow rate of the air conditioning equipment using high-temperature cooling water decreased while maintaining an equivalent amount of heat extraction. In conclusion, the efficiency of the equipment was further improved by operation control optimization.
AB - In recent years, energy conservation has become a major focus in the industrial sector. Many office buildings in Japan achieve energy savings by introducing highly efficient equipment and systems, such as high-temperature cooling water (14 °C), which increases heat source efficiency. However, such equipment requires adjustments to increase operational efficiency. In this case study, the efficiency of equipment using high-temperature cooling water was further improved through operation control optimization. The energy efficiency before and after the improvement was compared. The target building has chilled and hot water supplied to each floor from district heating and high-temperature chilled water supplied from cooling chillers on the rooftop. The energy consumption of two floors was evaluated: a subjective floor with equipment using high-temperature cooling water installed, and a common floor with a conventional system. After on-site verification, changes were made to the operation control of the cooling towers, condenser pumps, primary pumps, secondary pumps, and air handling units. As a result, the coefficient of performance of the water-cooled chiller and the whole system improved by 0.40 and 0.45, respectively. The flow rate of the air conditioning equipment using high-temperature cooling water decreased while maintaining an equivalent amount of heat extraction. In conclusion, the efficiency of the equipment was further improved by operation control optimization.
UR - http://www.scopus.com/inward/record.url?scp=85071862221&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=85071862221&partnerID=8YFLogxK
U2 - 10.1051/e3sconf/201911103071
DO - 10.1051/e3sconf/201911103071
M3 - Conference article
AN - SCOPUS:85071862221
SN - 2555-0403
VL - 111
JO - E3S Web of Conferences
JF - E3S Web of Conferences
M1 - 03071
T2 - 13th REHVA World Congress, CLIMA 2019
Y2 - 26 May 2019 through 29 May 2019
ER -