TY - JOUR
T1 - Energy consumption after great earthquake of east Japan
T2 - Development and analysis of DECC (data-base for energy consumption of commercial building) Part 2
AU - Takaguchi, Hiroto
AU - Yamamoto, Takaharu
AU - Kametani, Shigeki
AU - Hanzawa, Hisashi
AU - Yoshino, Hiroshi
AU - Asano, Yoshiharu
AU - Okumiya, Masaya
AU - Shimoda, Yoshiyuki
AU - Murakawa, Saburo
AU - Yoda, Hirotoshi
AU - Sakamoto, Yuzo
AU - Bogaki, Kazuaki
AU - Murakami, Shuzo
N1 - Copyright:
Copyright 2018 Elsevier B.V., All rights reserved.
PY - 2014/9/1
Y1 - 2014/9/1
N2 - Because of the lack of power in Tokyo and Tohoku due to Tohoku-Pacific Ocean Earthquake that occurred on March 11, 2011, ordinance of electric power usage restrictions were triggered for the first time in 37 years. Large consumers of more than 500kW electric power contract were asked to reduce power consumption of 15%. Furthermore, since the power plant was stopped across the country, power-saving and energy-saving measures have been implemented in almost all over Japan. We conducted the investigation on the power saving conditions in the summer of 2011, in order to grasp and analyze the actual condition of power saving which commercial buildings performed. When we compared the energy consumption of the total from April to September of 2011 with 2010, about Office building, Kanto Area showed the biggest reduction of 21.4%, and when we compared the peak load of electricity of 2011 with 2010, the large office building in Tohoku Area showed the biggest reduction of 23.6%.
AB - Because of the lack of power in Tokyo and Tohoku due to Tohoku-Pacific Ocean Earthquake that occurred on March 11, 2011, ordinance of electric power usage restrictions were triggered for the first time in 37 years. Large consumers of more than 500kW electric power contract were asked to reduce power consumption of 15%. Furthermore, since the power plant was stopped across the country, power-saving and energy-saving measures have been implemented in almost all over Japan. We conducted the investigation on the power saving conditions in the summer of 2011, in order to grasp and analyze the actual condition of power saving which commercial buildings performed. When we compared the energy consumption of the total from April to September of 2011 with 2010, about Office building, Kanto Area showed the biggest reduction of 21.4%, and when we compared the peak load of electricity of 2011 with 2010, the large office building in Tohoku Area showed the biggest reduction of 23.6%.
KW - Commercial buildings
KW - DECC
KW - Database
KW - Primary energy consumption intensity
UR - http://www.scopus.com/inward/record.url?scp=84907608980&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=84907608980&partnerID=8YFLogxK
U2 - 10.3130/aije.79.795
DO - 10.3130/aije.79.795
M3 - Article
AN - SCOPUS:84907608980
SN - 1348-0685
VL - 79
SP - 795
EP - 801
JO - Journal of Environmental Engineering (Japan)
JF - Journal of Environmental Engineering (Japan)
IS - 703
ER -