TY - JOUR
T1 - EVAHEART™
T2 - An Implantable Centrifugal Blood Pump for Long-Term Circulatory Support
AU - Yamazaki, Kenji
AU - Kihara, Shinichiro
AU - Akimoto, Takehide
AU - Tagusari, Osamu
AU - Kawai, Akihiko
AU - Umezu, Mitsuo
AU - Tomioka, Jun
AU - Kormos, Robert L.
AU - Griffith, Bartley P.
AU - Kurosawa, Hiromi
N1 - Copyright:
Copyright 2017 Elsevier B.V., All rights reserved.
PY - 2002/11
Y1 - 2002/11
N2 - Objective: We developed "EVAHEART™": a compact centrifugal blood pump system as an implantable left ventricular assist device for long-term circulatory support. The 55 × 64 mm pump is made from pure titanium, and weighs 370 g. The entire blood-contacting surface is covered with an anti-thrombogenic coating of diamond like carbon (DLC) or 2-methacryloyloxyethyl phosphorylcholine (MPC) to improve blood compatibility. Flows exceeding 12 L/min against 100 mmHg pressure at 2600 rpm was measured. A low-temperature mechanical seal with recirculating cooling system is used to seal the shaft. EVAHEART™ demonstrated an acceptably low hemolysis rate with normalized index of hemolysis of 0.005 ± 0.002 g/100L. Methods: We evaluated the pump in long-term in-vivo experiments with seven calves. Via left thoracotomy, we conducted left ventricular apex-descending aorta bypass, placing the pump in the left thoracic cavity. Results: Pump flow rates was maintained at 5-9 L/min, pump power consumption remained stable at 9-10 W in all cases, plasma free Hb levels were less than 15 mg/dl, and the seal system showed good seal capability throughout the experiments. The calves were sacrificed on schedule on postoperative day 200, 222, 142, 90, 151, 155, and 133. No thrombi formed on the blood contacting surface with either the DLC or MPC coating, and no major organ thromboembolisms occurred except for a few small renal infarcts. Conclusion: EVAHEART™ centrifugal blood pump demonstrated excellent performance in long-term in-vivo experiments.
AB - Objective: We developed "EVAHEART™": a compact centrifugal blood pump system as an implantable left ventricular assist device for long-term circulatory support. The 55 × 64 mm pump is made from pure titanium, and weighs 370 g. The entire blood-contacting surface is covered with an anti-thrombogenic coating of diamond like carbon (DLC) or 2-methacryloyloxyethyl phosphorylcholine (MPC) to improve blood compatibility. Flows exceeding 12 L/min against 100 mmHg pressure at 2600 rpm was measured. A low-temperature mechanical seal with recirculating cooling system is used to seal the shaft. EVAHEART™ demonstrated an acceptably low hemolysis rate with normalized index of hemolysis of 0.005 ± 0.002 g/100L. Methods: We evaluated the pump in long-term in-vivo experiments with seven calves. Via left thoracotomy, we conducted left ventricular apex-descending aorta bypass, placing the pump in the left thoracic cavity. Results: Pump flow rates was maintained at 5-9 L/min, pump power consumption remained stable at 9-10 W in all cases, plasma free Hb levels were less than 15 mg/dl, and the seal system showed good seal capability throughout the experiments. The calves were sacrificed on schedule on postoperative day 200, 222, 142, 90, 151, 155, and 133. No thrombi formed on the blood contacting surface with either the DLC or MPC coating, and no major organ thromboembolisms occurred except for a few small renal infarcts. Conclusion: EVAHEART™ centrifugal blood pump demonstrated excellent performance in long-term in-vivo experiments.
KW - Artificial heart
KW - Centrifugal blood pump
KW - EVAHEART
KW - Left ventricular assist device
UR - http://www.scopus.com/inward/record.url?scp=0036835036&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=0036835036&partnerID=8YFLogxK
U2 - 10.1007/BF02919636
DO - 10.1007/BF02919636
M3 - Article
C2 - 12478865
AN - SCOPUS:0036835036
SN - 1344-4964
VL - 50
SP - 461
EP - 465
JO - Japanese Journal of Thoracic and Cardiovascular Surgery
JF - Japanese Journal of Thoracic and Cardiovascular Surgery
IS - 11
ER -