TY - JOUR
T1 - Experimental vocal cord abduction impairment with an artificial vocal cord
AU - Isozaki, Eiji
AU - Tobisawa, Shinsuke
AU - Nishizawa, Misato
AU - Nakayama, Hideto
AU - Fukui, Kotaro
AU - Takanishi, Asuo
N1 - Copyright:
This record is sourced from MEDLINE®/PubMed®, a database of the U.S. National Library of Medicine
PY - 2009/7
Y1 - 2009/7
N2 - Non-invasive positive pressure ventilation (NPPV) has recently been applied to the patients with multiple system atrophy (MSA) with various respiratory complications including vocal cord abduction impairment and respiratory disturbance by the central origin. Any consensus guidelines on setting up the inspiratory positive airway pressure (IPAP) and expiratory one (EPAP), however, have not been raised yet. To investigate this problem, we made the upper airway tract model with moderately and severely narrow glottis using a training/test lung and the artificial vocal cord which was developed for a humanoid talking robot in Waseda University. The artificial vocal cord was molded out of a high performance thermoplastic rubber in imitation of the human larynx. Previous studies using with a high-speed camera and a sound analyzer showed that the artificial vocal cord resembled human larynx closely both morphologically and functionally. The opening and closing movements of the artificial vocal cord were observed fiberscopically under various conditions of IPAP (4-20 cmH2O) and EPAP (4-10 cmH2O). The maximal glottic width during inspiration and expiration were measured by a pair of calipers on the video-monitored display. Both of the moderately and the severely narrow artificial vocal cords without non-paralytic factors showed typical paradoxical movement showing adduction in inspiration and abduction in expiration, which is characteristic to vocal cord abductor impairment seen in MSA. In the model with moderately severe narrow glottis, this paradoxical movement was released under any positive pressures of continuous (CPAP) and bilevel (Bilevel PAP) modes. In the model with severely narrow glottis, however, there existed a threshold in setting up the optimal EPAP to release the paradoxical movement. In conclusion, EPAP-leading procedure seems to be preferable to IPAP-leading procedure to dilate the narrow glottis as a pneumatic splint in the managements of the patients with MSA presenting with a paralytic type of vocal cord abductor impairment.
AB - Non-invasive positive pressure ventilation (NPPV) has recently been applied to the patients with multiple system atrophy (MSA) with various respiratory complications including vocal cord abduction impairment and respiratory disturbance by the central origin. Any consensus guidelines on setting up the inspiratory positive airway pressure (IPAP) and expiratory one (EPAP), however, have not been raised yet. To investigate this problem, we made the upper airway tract model with moderately and severely narrow glottis using a training/test lung and the artificial vocal cord which was developed for a humanoid talking robot in Waseda University. The artificial vocal cord was molded out of a high performance thermoplastic rubber in imitation of the human larynx. Previous studies using with a high-speed camera and a sound analyzer showed that the artificial vocal cord resembled human larynx closely both morphologically and functionally. The opening and closing movements of the artificial vocal cord were observed fiberscopically under various conditions of IPAP (4-20 cmH2O) and EPAP (4-10 cmH2O). The maximal glottic width during inspiration and expiration were measured by a pair of calipers on the video-monitored display. Both of the moderately and the severely narrow artificial vocal cords without non-paralytic factors showed typical paradoxical movement showing adduction in inspiration and abduction in expiration, which is characteristic to vocal cord abductor impairment seen in MSA. In the model with moderately severe narrow glottis, this paradoxical movement was released under any positive pressures of continuous (CPAP) and bilevel (Bilevel PAP) modes. In the model with severely narrow glottis, however, there existed a threshold in setting up the optimal EPAP to release the paradoxical movement. In conclusion, EPAP-leading procedure seems to be preferable to IPAP-leading procedure to dilate the narrow glottis as a pneumatic splint in the managements of the patients with MSA presenting with a paralytic type of vocal cord abductor impairment.
UR - http://www.scopus.com/inward/record.url?scp=70350752484&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=70350752484&partnerID=8YFLogxK
U2 - 10.5692/clinicalneurol.49.407
DO - 10.5692/clinicalneurol.49.407
M3 - Article
C2 - 19715168
AN - SCOPUS:70350752484
SN - 0009-918X
VL - 49
SP - 407
EP - 413
JO - Clinical Neurology
JF - Clinical Neurology
IS - 7
ER -