TY - JOUR
T1 - Fault Detection and Diagnosis in a Continuous Process with Uncertainly Normal Situations
AU - Tsuge, Yoshifumi
AU - Mori, Kazushi
AU - Tateno, Shigeyuki
AU - Matsuyama, Hisayoshi
N1 - Copyright:
Copyright 2016 Elsevier B.V., All rights reserved.
PY - 1995
Y1 - 1995
N2 - Fault detection and diagnosis of a continuous process with input fluctuations such as load fluctuations can not be simply performed because of the difficulty of detecting the abnormality in the process, where normal values of state variables are uncertainly time-varying due to input fluctuations. In this study, normal values of output variables are estimated by the auto regressive exogenous model (ARX model). The measured value of an output variable is classified as 5-range signs (+, +?, 0, -?, -) by simultaneously performing two sequential probability ratio tests (SPRTs) based on the error residual between estimated and measured values : one test examines whether it is normal or higher than normal, the other examines whether it is normal or lower than normal. A combination of signs given to all the output variables is called a “pattern,” which is considered to represent an abnormal situation occurring in the process. Then, the fault diagnosis algorithm based on signed directed graph can deduce the fault origin that causes the pattern. The effectiveness of this approach is demonstrated through experiments with a tank-pipeline system.
AB - Fault detection and diagnosis of a continuous process with input fluctuations such as load fluctuations can not be simply performed because of the difficulty of detecting the abnormality in the process, where normal values of state variables are uncertainly time-varying due to input fluctuations. In this study, normal values of output variables are estimated by the auto regressive exogenous model (ARX model). The measured value of an output variable is classified as 5-range signs (+, +?, 0, -?, -) by simultaneously performing two sequential probability ratio tests (SPRTs) based on the error residual between estimated and measured values : one test examines whether it is normal or higher than normal, the other examines whether it is normal or lower than normal. A combination of signs given to all the output variables is called a “pattern,” which is considered to represent an abnormal situation occurring in the process. Then, the fault diagnosis algorithm based on signed directed graph can deduce the fault origin that causes the pattern. The effectiveness of this approach is demonstrated through experiments with a tank-pipeline system.
KW - Fault Detection
KW - Fault Diagnosis
KW - Hypothesis Test
KW - Process System
KW - Signed Directed Graph
UR - http://www.scopus.com/inward/record.url?scp=33646335894&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=33646335894&partnerID=8YFLogxK
U2 - 10.1252/kakoronbunshu.21.565
DO - 10.1252/kakoronbunshu.21.565
M3 - Article
AN - SCOPUS:33646335894
SN - 0386-216X
VL - 21
SP - 565
EP - 572
JO - Kagaku Kogaku Ronbunshu
JF - Kagaku Kogaku Ronbunshu
IS - 3
ER -