T1 - Field survey in office introduced task/ambient system with ceiling radiation membrane
AU - Furuya, Keiichi
AU - Tanabe, Shin Ichi
AU - Nishihara, Naoe
AU - Wada, Kazuki
AU - Yamamoto, Taizou
PY - 2012/12/1
Y1 - 2012/12/1
N2 - The main purpose of this study was to determine the indoor environment in an office introduced a task/ambient system with ceiling radiation membrane and to reveal the effects of this system on workers' thermal comfort and productivity. For a month in the summer of 2010, a field survey was conducted in an office located in Tokyo. In this survey, indoor environment and operation data were measured, and a subjective survey was conducted about the indoor environment using a questionnaire. As a result, it was found that a personal diffuser that allows a worker to individually adjust the air volume in their area improves their thermal satisfaction and subjective performance. However, more than 60% of the workers were dissatisfied with the thermal environment when the setpoint was at 28°C and they could adjust the air volume (28-Ctl condition). Workers' thermal satisfaction and subjective performance would be improved by taking some measures such as lowering the air temperature setpoint, making the orientation of the personal diffusers adjustable, and increasing the maximum air volume of the personal diffuser.
AB - The main purpose of this study was to determine the indoor environment in an office introduced a task/ambient system with ceiling radiation membrane and to reveal the effects of this system on workers' thermal comfort and productivity. For a month in the summer of 2010, a field survey was conducted in an office located in Tokyo. In this survey, indoor environment and operation data were measured, and a subjective survey was conducted about the indoor environment using a questionnaire. As a result, it was found that a personal diffuser that allows a worker to individually adjust the air volume in their area improves their thermal satisfaction and subjective performance. However, more than 60% of the workers were dissatisfied with the thermal environment when the setpoint was at 28°C and they could adjust the air volume (28-Ctl condition). Workers' thermal satisfaction and subjective performance would be improved by taking some measures such as lowering the air temperature setpoint, making the orientation of the personal diffusers adjustable, and increasing the maximum air volume of the personal diffuser.
KW - Field survey
KW - Radiant cooling system
KW - Subjective vote
KW - Task/ambient
UR - http://www.scopus.com/inward/record.url?scp=84883430690&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=84883430690&partnerID=8YFLogxK
M3 - Conference contribution
AN - SCOPUS:84883430690
SN - 9781627480758
T3 - 10th International Conference on Healthy Buildings 2012
SP - 1443
EP - 1448
BT - 10th International Conference on Healthy Buildings 2012
T2 - 10th International Conference on Healthy Buildings 2012
Y2 - 8 July 2012 through 12 July 2012
ER -