Abstract
Investigation of fire load in 6 school gymnasiums, 2 for each of elementary, junior high and senior high schools in Akita and Fukushima Prefectures, is conducted for the performance oriented fire safety design of school gymnasium buildings under the localized fire concept. It reveals notable insufficiency of storages for exercise equipments which results in the increase of fire load in arenas and may make the localized-fire to achieve. A guideline has been proposed to prepare sufficient storage spaces in school gymnasium buildings.
Original language | English |
---|---|
Pages (from-to) | 549-554 |
Number of pages | 6 |
Journal | AIJ Journal of Technology and Design |
Volume | 17 |
Issue number | 36 |
DOIs | |
Publication status | Published - 2011 Jun |
Externally published | Yes |
Keywords
- Calorific value
- Fire load
- Large space wooden building
- Localized fire
- School gymnasium building
ASJC Scopus subject areas
- Architecture
- Building and Construction