Fire resistance of Japanese traditional timber-frame soil internal walls exposed to both-sides heating

Yoshinao Sawano*, Yuji Hasemi, Noboru Yasui, Atsushi Ogawa, Hiroyuki Hirai, Tadanori Kimura, Koichi Yamamoto

*Corresponding author for this work

Research output: Contribution to journalArticlepeer-review

1 Citation (Scopus)

Abstract

Mechanical fire resistance of internal load bearing walls under both-sides heating is important for the prevention of collapse of a dwelling in a fire. Feasibility of the 45 minutes mechanical fire resistance with Japanese traditional timber-frame soil internal wall is studied for this purpose. The tests were initiated with intermediate scale specimens for the examination of the charring and internal temperature field of the column and then loaded tests under both-sides exposure were conducted on two 1-story tall bare-timber wall specimens. The tests suggest significant influence of the mortises of columns for horizontal timber bars on the buckling of walls. The conventional predictive method of the mechanical fire resistance of bare timber walls is then modified for the tested configuration.

Original languageEnglish
Pages (from-to)1-7
Number of pages7
JournalJournal of Environmental Engineering
Volume74
Issue number635
DOIs
Publication statusPublished - 2009 Jan

Keywords

  • Bare Timber Post and Beam Construction
  • Buckling
  • Loaded Fire Test
  • Mechanical Fire resistance
  • Post
  • Traditional Townhouse

ASJC Scopus subject areas

  • Environmental Engineering

Fingerprint

Dive into the research topics of 'Fire resistance of Japanese traditional timber-frame soil internal walls exposed to both-sides heating'. Together they form a unique fingerprint.