Fundamental study on control effect of TMD floor system under seismic excitation

Ping Xiang, Akira Nishitani

Research output: Contribution to journalArticlepeer-review

4 Citations (Scopus)

Abstract

A new passive control system integrating "TMD floor system (TMDFS)" into a building is presented in this paper. TMDFS takes advantages of the characteristics of floor isolation system (FIS) and tuned mass damper (TMD). The proposed system utilizes floors as TMDs. Advantageously, TMD floor could achieve large mass ratio without any additional masses attached. Basic effectiveness of TMDFS is demonstrated by conducting a shaking table test of a single TMD floor integrated model structure. After confirming that the obtained experimental results are well simulated with the theoretical model composed of the same parameters as the test model structure, a multiple-TMD-floor integrated system is investigated. It is concluded that TMDFS has a great potential of achievingsatisfactory vibration control effect for buildings.

Original languageEnglish
Pages (from-to)2093-2101
Number of pages9
JournalJournal of Structural and Construction Engineering
Volume78
Issue number694
DOIs
Publication statusPublished - 2013 Dec

Keywords

  • Floor isolation system
  • Optimum design
  • Shaking table test
  • TMD floor system
  • Tuned mass damper

ASJC Scopus subject areas

  • Architecture
  • Building and Construction

Fingerprint