TY - GEN
T1 - Hand-operated natural ventilation windows of skyscraper building
AU - Iwahashi, Yuko
AU - Kim, Jeongsoo
AU - Tanabe, Shin Ichi
AU - Kawaguchi, Tomomi
AU - Yasuda, Ken Ichi
PY - 2011
Y1 - 2011
N2 - Recently, buildings with natural ventilation system have increased from the points of indoor comfort and energy conservation. In this study, field measurement, questionnaire survey and BEMS-data analysis were conducted at a skyscraper office building with hand-operated natural ventilation windows in order to investigate the window performance and actual window operation during a year. According to the measurement survey, the temperature of the air that flowed in through the window has risen remarkably in the cavity of double-skin due to sunlight. From questionnaire survey, we found that the workers feel the necessity of the natural ventilation windows, and prefer manual control to automatic control. From the result of BEMS-data analysis, it was indicated that the window open rate had a high correlation with the outdoor temperature, and reached its peak at around 21 °C. Furthermore, it was shown that a regular enlightenment activity of appropriate window operation led to energy conservation.
AB - Recently, buildings with natural ventilation system have increased from the points of indoor comfort and energy conservation. In this study, field measurement, questionnaire survey and BEMS-data analysis were conducted at a skyscraper office building with hand-operated natural ventilation windows in order to investigate the window performance and actual window operation during a year. According to the measurement survey, the temperature of the air that flowed in through the window has risen remarkably in the cavity of double-skin due to sunlight. From questionnaire survey, we found that the workers feel the necessity of the natural ventilation windows, and prefer manual control to automatic control. From the result of BEMS-data analysis, it was indicated that the window open rate had a high correlation with the outdoor temperature, and reached its peak at around 21 °C. Furthermore, it was shown that a regular enlightenment activity of appropriate window operation led to energy conservation.
KW - Actual operation
KW - BEMS
KW - Double-skin
KW - Energy conservation
KW - Enlightenment activity
UR - http://www.scopus.com/inward/record.url?scp=84880533619&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=84880533619&partnerID=8YFLogxK
M3 - Conference contribution
AN - SCOPUS:84880533619
SN - 9781627482721
T3 - 12th International Conference on Indoor Air Quality and Climate 2011
SP - 1409
EP - 1414
BT - 12th International Conference on Indoor Air Quality and Climate 2011
T2 - 12th International Conference on Indoor Air Quality and Climate 2011
Y2 - 5 June 2011 through 10 June 2011
ER -