Abstract
Double-skin façade is getting more and more attention as it provides many possibilities for energy conservation and at the same time creates good indoor environment. In this paper, natural ventilation performance of a double-skin façade is highlighted. A prototype building is proposed, which is thought to be an eight-storey office building with an atrium space in the north side. The south façade of the building is a double-skin façade and a thermal storage space called solar chimney is considered above the double-skin space. Actually, the double-skin space is connected with the chimney channel. Reduced scale model experiments and computational fluid dynamics (CFD) analysis are carried out in this research to evaluate the natural ventilation performance of the prototype building.
Original language | English |
---|---|
Pages (from-to) | 411-418 |
Number of pages | 8 |
Journal | Energy and Buildings |
Volume | 37 |
Issue number | 4 |
DOIs | |
Publication status | Published - 2005 Apr |
Keywords
- CFD
- Double-skin façade
- Model experiments
- Natural ventilation
- Solar chimney
ASJC Scopus subject areas
- Civil and Structural Engineering
- Building and Construction
- Mechanical Engineering
- Electrical and Electronic Engineering