TY - JOUR
T1 - Non-invasive assessment of cardiac output during exercise in healthy young humans
T2 - Comparison between Modelflow method and Doppler echocardiography method
AU - Sugawara, J.
AU - Tanabe, T.
AU - Miyachi, M.
AU - Yamamoto, K.
AU - Takahashi, K.
AU - Iemitsu, M.
AU - Otsuki, T.
AU - Homma, S.
AU - Maeda, S.
AU - Ajisaka, R.
AU - Matsuda, M.
PY - 2003/12
Y1 - 2003/12
N2 - Aims: The Modelflow method can estimate cardiac output from arterial blood pressure waveforms using a three-element model of aortic input impedance (aortic characteristic impedance, arterial compliance, and systemic vascular resistance). We tested the reliability of a non-invasive cardiac output estimation during submaximal exercise using the Modelflow method from finger arterial pressure waveforms collected by Portapres in healthy young humans. Methods: The Doppler echocardiography method was used as a reference method. Sixteen healthy young subjects (nine males and seven females) performed a multi-stage cycle ergometer exercise at an intensity corresponding to 70, 90, 110 and 130% of their individual ventilatory threshold for 2 min each. The simultaneous estimation of cardiac output (15 s averaged data) using the Modelflow and Doppler echocardiography methods was performed at rest and during exercise. Results and Conclusion: The Modelflow-estimated cardiac output correlated significantly with the simultaneous estimates by the Doppler method in all subjects (r = 0.87, P < 0.0001) and the SE of estimation was 1.93 L min-1. Correlation coefficients in each subject ranged from 0.91 to 0.98. Although the Modelflow method overestimated cardiac output, the errors between two estimates were not significantly different among the exercise levels. These results suggest that the Modelflow method using Portapres could provide a reliable estimation of the relative change in cardiac output non-invasively and continuously during submaximal exercise in healthy young humans, at least in terms of the relative changes in cardiac output.
AB - Aims: The Modelflow method can estimate cardiac output from arterial blood pressure waveforms using a three-element model of aortic input impedance (aortic characteristic impedance, arterial compliance, and systemic vascular resistance). We tested the reliability of a non-invasive cardiac output estimation during submaximal exercise using the Modelflow method from finger arterial pressure waveforms collected by Portapres in healthy young humans. Methods: The Doppler echocardiography method was used as a reference method. Sixteen healthy young subjects (nine males and seven females) performed a multi-stage cycle ergometer exercise at an intensity corresponding to 70, 90, 110 and 130% of their individual ventilatory threshold for 2 min each. The simultaneous estimation of cardiac output (15 s averaged data) using the Modelflow and Doppler echocardiography methods was performed at rest and during exercise. Results and Conclusion: The Modelflow-estimated cardiac output correlated significantly with the simultaneous estimates by the Doppler method in all subjects (r = 0.87, P < 0.0001) and the SE of estimation was 1.93 L min-1. Correlation coefficients in each subject ranged from 0.91 to 0.98. Although the Modelflow method overestimated cardiac output, the errors between two estimates were not significantly different among the exercise levels. These results suggest that the Modelflow method using Portapres could provide a reliable estimation of the relative change in cardiac output non-invasively and continuously during submaximal exercise in healthy young humans, at least in terms of the relative changes in cardiac output.
KW - Cardiac output
KW - Doppler echocardiography
KW - Finger arterial pressure waveform
UR - http://www.scopus.com/inward/record.url?scp=0346880106&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=0346880106&partnerID=8YFLogxK
U2 - 10.1046/j.0001-6772.2003.01211.x
DO - 10.1046/j.0001-6772.2003.01211.x
M3 - Article
C2 - 14656373
AN - SCOPUS:0346880106
SN - 0001-6772
VL - 179
SP - 361
EP - 366
JO - Acta Physiologica Scandinavica
JF - Acta Physiologica Scandinavica
IS - 4
ER -