T1 - Optical imaging of arteriovenous fistula for clinical application
T2 - Clarification of transillumination image of blood vessel by image-subtraction
AU - Kamiyama, Hideaki
AU - Kitama, Masataka
AU - Shimizu, Hisae O.
AU - Yamashita, Masaji
AU - Yokoyama, Toru
AU - Kojima, Yohichiro
AU - Shimizu, Koichi
N1 - Publisher Copyright:
© 2017, Japan Soc. of Med. Electronics and Biol. Engineering. All rights reserved.
PY - 2017
Y1 - 2017
N2 - We have proposed a noninvasive technique to observe an arteriovenous fistula using an optical transillumination image of a blood vessel. To improve the accuracy of inner-diameter measurement of the vessel, we examined the effectiveness of the imagesubtraction technique using multi-wavelength light sources. In the experiment, we fabricated a model-phantom to simulate a human forearm. It contained the tube filled with replaceable absorber liquid which simulated the blood in different wavelengths of illuminating light. The transillumination images of the blood column were recorded with the liquid of different absorption coefficients. The imagesubtraction technique was applied and the images were analyzed. With the subtraction, the sharpness of the column image was improved by 55%, and the error in the diameter measurement was reduced from 28% to 4%. This result verified the effectiveness of the image-subtraction to promote the clinical application of the proposed technique for the controlled care of the arteriovenous fistula.
AB - We have proposed a noninvasive technique to observe an arteriovenous fistula using an optical transillumination image of a blood vessel. To improve the accuracy of inner-diameter measurement of the vessel, we examined the effectiveness of the imagesubtraction technique using multi-wavelength light sources. In the experiment, we fabricated a model-phantom to simulate a human forearm. It contained the tube filled with replaceable absorber liquid which simulated the blood in different wavelengths of illuminating light. The transillumination images of the blood column were recorded with the liquid of different absorption coefficients. The imagesubtraction technique was applied and the images were analyzed. With the subtraction, the sharpness of the column image was improved by 55%, and the error in the diameter measurement was reduced from 28% to 4%. This result verified the effectiveness of the image-subtraction to promote the clinical application of the proposed technique for the controlled care of the arteriovenous fistula.
KW - Arteriovenous fistula
KW - Image-subtraction
KW - Near-infrared light
KW - Transillumination imaging
UR - http://www.scopus.com/inward/record.url?scp=85029868422&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=85029868422&partnerID=8YFLogxK
U2 - 10.11239/jsmbe.55Annual.593
DO - 10.11239/jsmbe.55Annual.593
M3 - Article
AN - SCOPUS:85029868422
SN - 1347-443X
VL - 55
SP - 593
EP - 594
JO - BME = Bio medical engineering / henshu, Nihon ME Gakkai
JF - BME = Bio medical engineering / henshu, Nihon ME Gakkai
IS - Proc
ER -