TY - GEN
T1 - Peristaltic hemodynamics of a new pediatric circulatory assist system for Fontan circulation using shape memory alloy fibers
AU - Yamada, A.
AU - Shiraishi, Y.
AU - Miura, H.
AU - Yambe, T.
AU - Omran, M. H.
AU - Shiga, T.
AU - Tsuboko, Y.
AU - Homma, D.
AU - Yamagishi, M.
PY - 2013
Y1 - 2013
N2 - Fontan procedure is one of the common surgical treatments of congenital heart diseases. Patients with Fontan circulation have single ventricle in the systemic circulation with the total cavopulmonary connection. We have been developing a pulmonary circulatory assist device using shape memory alloy fibers for Fontan circulation with total cavopulmonary connection. It consisted of the shape memory alloy fibers, the diameter of which are 100 μm. The fibers could wrap the ePTFE conduit for Fontan TCPC connection from the outside. We designed the sequential motion control system for sophisticated pulmonary hemodynamics by the pulsatile flow generation. In order to achieve pulsatile flow assistance in pulmonary arterial system, we fabricated a mechanical structure by sequential contraction of shape memory alloy fibers. Then, we developed a sequential contraction controller for the assist system, which could reproduce the wall contractile velocity at 6.0 to 20.0 cm/sec. We examined hemodynamic characteristic of its function using a mock circulatory system, which consisted of two overflow tanks representing venous and pulmonary arterial pressures in Fontan circulation. As a result, the pulmonary circulation assist device with sequential contraction could achieve effective promotion of the pulsatility in pulmonary arterial flow.
AB - Fontan procedure is one of the common surgical treatments of congenital heart diseases. Patients with Fontan circulation have single ventricle in the systemic circulation with the total cavopulmonary connection. We have been developing a pulmonary circulatory assist device using shape memory alloy fibers for Fontan circulation with total cavopulmonary connection. It consisted of the shape memory alloy fibers, the diameter of which are 100 μm. The fibers could wrap the ePTFE conduit for Fontan TCPC connection from the outside. We designed the sequential motion control system for sophisticated pulmonary hemodynamics by the pulsatile flow generation. In order to achieve pulsatile flow assistance in pulmonary arterial system, we fabricated a mechanical structure by sequential contraction of shape memory alloy fibers. Then, we developed a sequential contraction controller for the assist system, which could reproduce the wall contractile velocity at 6.0 to 20.0 cm/sec. We examined hemodynamic characteristic of its function using a mock circulatory system, which consisted of two overflow tanks representing venous and pulmonary arterial pressures in Fontan circulation. As a result, the pulmonary circulation assist device with sequential contraction could achieve effective promotion of the pulsatility in pulmonary arterial flow.
UR - http://www.scopus.com/inward/record.url?scp=84886538533&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=84886538533&partnerID=8YFLogxK
U2 - 10.1109/EMBC.2013.6609592
DO - 10.1109/EMBC.2013.6609592
M3 - Conference contribution
C2 - 24109779
AN - SCOPUS:84886538533
SN - 9781457702167
T3 - Proceedings of the Annual International Conference of the IEEE Engineering in Medicine and Biology Society, EMBS
SP - 683
EP - 686
BT - 2013 35th Annual International Conference of the IEEE Engineering in Medicine and Biology Society, EMBC 2013
T2 - 2013 35th Annual International Conference of the IEEE Engineering in Medicine and Biology Society, EMBC 2013
Y2 - 3 July 2013 through 7 July 2013