N2 - Since lithium salts are used as pharmaceutically active compounds against manic-depressive psychosis, there is a demand to monitor the lithium concentration in blood in the narrow range of 0.6-1.2 mM effectively and safely. Here we report on an optical sensor approach for the determination of Li +, based on the design and synthesis of a novel lithium fluoroionophore KLI-1 and its polymer immobilizable derivative KLI-2, and the application to an optode. The novel lithium fluoroionophores rely on a tetramethyl "blocking subunit" bearing 14-crown-4 as a Li +-selective binding site and 4-methylcoumarin as a fluorophore, intramolecularly connected to show ICT-type wavelength shift for ratiometric fluorescence measurements. The fluoroionophores showed high selectivity for Li+ with binding-induced blue shift in the fluorescence spectra, no response to major biological interfering cations (K+, Ca 2+, Mg2+), a selectivity of log kLi+,Na+ = -2.4 over Na+ in solution, and no response to pH in the range of pH 3-10. A hydrophilic optode membrane with KLI-2 immobilized also showed good selectivity for Li+, pH independence in the physiological range (pH 6-8), and fully reversible signal changes. KLI-1 and KLI-2 are excellent Li + fluorescent chemosensors that can be applied to quantitative measurements of lithium in clinical samples, although possible interference from Na+ has to be considered at the lower therapeutic level of Li +.
AB - Since lithium salts are used as pharmaceutically active compounds against manic-depressive psychosis, there is a demand to monitor the lithium concentration in blood in the narrow range of 0.6-1.2 mM effectively and safely. Here we report on an optical sensor approach for the determination of Li +, based on the design and synthesis of a novel lithium fluoroionophore KLI-1 and its polymer immobilizable derivative KLI-2, and the application to an optode. The novel lithium fluoroionophores rely on a tetramethyl "blocking subunit" bearing 14-crown-4 as a Li +-selective binding site and 4-methylcoumarin as a fluorophore, intramolecularly connected to show ICT-type wavelength shift for ratiometric fluorescence measurements. The fluoroionophores showed high selectivity for Li+ with binding-induced blue shift in the fluorescence spectra, no response to major biological interfering cations (K+, Ca 2+, Mg2+), a selectivity of log kLi+,Na+ = -2.4 over Na+ in solution, and no response to pH in the range of pH 3-10. A hydrophilic optode membrane with KLI-2 immobilized also showed good selectivity for Li+, pH independence in the physiological range (pH 6-8), and fully reversible signal changes. KLI-1 and KLI-2 are excellent Li + fluorescent chemosensors that can be applied to quantitative measurements of lithium in clinical samples, although possible interference from Na+ has to be considered at the lower therapeutic level of Li +.
UR - http://www.scopus.com/inward/record.url?scp=33846945062&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=33846945062&partnerID=8YFLogxK
U2 - 10.1021/ac061674g
DO - 10.1021/ac061674g
M3 - Article
C2 - 17263359
AN - SCOPUS:33846945062
SN - 0003-2700
VL - 79
SP - 1237
EP - 1242
JO - Analytical Chemistry
JF - Analytical Chemistry
IS - 3
ER -