Abstract
Authors have an idea for applying the heat driven pump to a heat device, for example, for lifting condensation liquid from the condenser to the evaporator placed higher level in a downward heat pipe. This pump was developed by the authors and has the advantages of avoiding moving parts and of being potentially cheaper because the construction is very sample. Moreover this pump does not need external mechanical energy, or electricity and can be operated with minimum maintenance. In this paper, the operating characteristic and the applications the authors are considering will be shown.
Original language | English |
---|---|
Title of host publication | Proceedings of the International Conference on Energy and Environment, ICEE |
Place of Publication | New York, NY, United States |
Publisher | Begell House Inc |
Pages | 538-542 |
Number of pages | 5 |
Publication status | Published - 1996 |
Externally published | Yes |
Event | Proceedings of the 1995 International Conference on Energy and Environment, ICEE - Shanghai, China Duration: 1995 May 1 → 1995 May 1 |
Other
Other | Proceedings of the 1995 International Conference on Energy and Environment, ICEE |
---|---|
City | Shanghai, China |
Period | 95/5/1 → 95/5/1 |
ASJC Scopus subject areas
- Engineering(all)