TY - JOUR
T1 - Radioimmunoassay for an analog of thyrotrophin-releasing hormone, γ-butyrolactone-γ-carbonyl-l-histidyl-l-prolinamide (DN-1417)
AU - Shiota, K.
AU - Miyake, A.
AU - Tsunoda, C.
AU - Oka, Y.
AU - Nagawa, Y.
AU - Nakayama, R.
PY - 1982/5/28
Y1 - 1982/5/28
N2 - A heterologous radioimmunoassay method was established to determine plasma levels of γ-butyrolactone-γ-carbonyl-L-histidyl-L-prolinamide (DN-1417). As this compound is unstable in the incubation buffer, we introduced a conversion step. DN-1417 in the plasma was extracted with a solution of isopropanol-isobutylamine (4 : 1) and incubation was performed at room temperature for 2 h for the conversion of DN-1417 into N-[2-hydroxy-4-(isobutylcarbamoyl)butyryl]-L-histidyl-L-prolinamide (DN-isobutylamide). 125I-labeled 2-hydroxy-4-carboxybutyryl-L-histidyl-L-prolinamide and antisera, which was raised in the rabbit using an esterified derivative of DN-1417 conjugated with BSA as an antigen, were used for a sensitive radioimmunoassay of DN-isobutylamide. In this system, 0.2 ng DN-isobutylamide/ml plasma, equivalent to 0.16 ng DN-1417/ml, was detected and there was no apparent interference from its metabolites. The within-assay coefficients of variation were 7.6% at 7.73 ng/tube and 13.7% at 1.32 ng/tube. The between-assay coefficients of variation were 16.1% at 6.43 ng/tube and 12.2% at 1.20 ng/tube. The mean recovery rate of the assay system was 76.0 ± 3.2% (S.E.M.).
AB - A heterologous radioimmunoassay method was established to determine plasma levels of γ-butyrolactone-γ-carbonyl-L-histidyl-L-prolinamide (DN-1417). As this compound is unstable in the incubation buffer, we introduced a conversion step. DN-1417 in the plasma was extracted with a solution of isopropanol-isobutylamine (4 : 1) and incubation was performed at room temperature for 2 h for the conversion of DN-1417 into N-[2-hydroxy-4-(isobutylcarbamoyl)butyryl]-L-histidyl-L-prolinamide (DN-isobutylamide). 125I-labeled 2-hydroxy-4-carboxybutyryl-L-histidyl-L-prolinamide and antisera, which was raised in the rabbit using an esterified derivative of DN-1417 conjugated with BSA as an antigen, were used for a sensitive radioimmunoassay of DN-isobutylamide. In this system, 0.2 ng DN-isobutylamide/ml plasma, equivalent to 0.16 ng DN-1417/ml, was detected and there was no apparent interference from its metabolites. The within-assay coefficients of variation were 7.6% at 7.73 ng/tube and 13.7% at 1.32 ng/tube. The between-assay coefficients of variation were 16.1% at 6.43 ng/tube and 12.2% at 1.20 ng/tube. The mean recovery rate of the assay system was 76.0 ± 3.2% (S.E.M.).
KW - DN-1417
KW - radioimmunoassay
KW - TRH analogs
KW - γ-butyrolactone-γ-carbonyl-L-histidyl-L-prolinamide
UR - http://www.scopus.com/inward/record.url?scp=0020068839&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=0020068839&partnerID=8YFLogxK
U2 - 10.1016/0022-1759(82)90383-0
DO - 10.1016/0022-1759(82)90383-0
M3 - Article
C2 - 6809831
AN - SCOPUS:0020068839
SN - 0022-1759
VL - 51
SP - 69
EP - 80
JO - Journal of Immunological Methods
JF - Journal of Immunological Methods
IS - 1
ER -