TY - JOUR
T1 - Temperature Profile Measurement in Simulated Fuel Assembly Structure with Wire-Mesh Technology
AU - Takiguchi, Hiroki
AU - Furuya, Masahiro
AU - Arai, Takahiro
N1 - Publisher Copyright:
© 2018 Hiroki Takiguchi et al.
PY - 2018
Y1 - 2018
N2 - When light water reactor (LWR) is subject to a cold shutdown, it needs to be cooled with pure water or seawater to prevent the core melting. To precisely evaluate the cooling characteristics in the fuel assembly, a measurement method capable of installing to the fuel assembly structure and determining the temperature distribution with high temporal resolution, high spatial resolution, and in multidimension is required. Furthermore, it is more practical if applicable to a pressure range up to the rated pressure 16 MPa of a pressurized water reactor (PWR). In this study, we applied the principle of the wire-mesh sensor technology used in the void fraction measurement to the temperature measurement and developed a simulated fuel assembly (bundle) test loop with installing the temperature profile sensors. To investigate the measurement performance in the bundle test section, it was confirmed that a predetermined temperature calibration line with respect to time-average impedance was calculated and became a function of temperature. To evaluate the followability of measurement in a transient temperature change process, we fabricated a 16 × 16 wire-mesh sensor device and measured the hot-water jet-mixing process into the cold-water pool in real time and calculated the temperature profile from the temperature calibration line obtained in advance from each measurement point. In addition, the sensors applied to three-dimensional temperature distribution measurement of a complex flow field in the bundle structure. The axial and cross-sectional profiles of temperature were quantified in the forced flow field with nonboiling when the 5×5 bundle was heated by energization.
AB - When light water reactor (LWR) is subject to a cold shutdown, it needs to be cooled with pure water or seawater to prevent the core melting. To precisely evaluate the cooling characteristics in the fuel assembly, a measurement method capable of installing to the fuel assembly structure and determining the temperature distribution with high temporal resolution, high spatial resolution, and in multidimension is required. Furthermore, it is more practical if applicable to a pressure range up to the rated pressure 16 MPa of a pressurized water reactor (PWR). In this study, we applied the principle of the wire-mesh sensor technology used in the void fraction measurement to the temperature measurement and developed a simulated fuel assembly (bundle) test loop with installing the temperature profile sensors. To investigate the measurement performance in the bundle test section, it was confirmed that a predetermined temperature calibration line with respect to time-average impedance was calculated and became a function of temperature. To evaluate the followability of measurement in a transient temperature change process, we fabricated a 16 × 16 wire-mesh sensor device and measured the hot-water jet-mixing process into the cold-water pool in real time and calculated the temperature profile from the temperature calibration line obtained in advance from each measurement point. In addition, the sensors applied to three-dimensional temperature distribution measurement of a complex flow field in the bundle structure. The axial and cross-sectional profiles of temperature were quantified in the forced flow field with nonboiling when the 5×5 bundle was heated by energization.
UR - http://www.scopus.com/inward/record.url?scp=85057386765&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=85057386765&partnerID=8YFLogxK
U2 - 10.1155/2018/2631084
DO - 10.1155/2018/2631084
M3 - Article
AN - SCOPUS:85057386765
SN - 1687-6075
VL - 2018
JO - Science and Technology of Nuclear Installations
JF - Science and Technology of Nuclear Installations
M1 - 2631084
ER -