TY - JOUR
T1 - Testing and optimizing the performance of a floor-based task conditioning system
AU - Bauman, F. S.
AU - Arens, E. A.
AU - Tanabe, S.
AU - Zhang, H.
AU - Baharlo, A.
N1 - Funding Information:
The research reported here was funded by the California Institute for Energy Efficiency (CIEE), a research unit of the University of California. Publication of research results does not imply CIEE endorsement of or agreement with these findings, nor that of any CIEE sponsor. We would like to acknowledge the support and technical assistance of Gene Brager of Dynamic Building Systems and John Zeren, both formerly with Tate Access Floors, Jessup, MD. This research was also aided significantly by generous furniture and partition donations from Steelcase, Inc., Grand Rapids, MI. The authors also appreciate the administrative support provided by Nora Watanabe of the Center for Environmental Design Research, University of California, Berkeley.
PY - 1995/8
Y1 - 1995/8
N2 - During recent years an increasing amount of attention has been paid to air distribution systems that individually condition the immediate environments of office workers within their workstations. As with task lighting systems, the controls for these 'task conditioning' systems are partially or entirely decentralized and under the control of the occupants. Among the primary types of task conditioning systems (floor-, desktop- and partition-based), floor-based designs are the most common, having been widely developed and used in South Africa and Europe, and are now gaining acceptance in the United States. This paper reports the results of recently completed laboratory measurements investigating the thermal performance of a floor-based task conditioning system. The experiments were performed in a controlled environment chamber configured to resemble a modern office space with modular workstation furniture and partitions. Tests were conducted to study the effects of supply volume, supply temperature, supply direction, and heat load levels in the space. In addition to detailed temperature and velocity measurements, a new skin-temperature-controlled thermal manikin was used to evaluate the non-uniform thermal environments produced by the floor-based system, in both sitting and standing positions. Under the low to intermediate supply volumes investigated in this study, the overall performance of the floor-based system resembled that of displacement ventilation systems. Primarily by controlling supply volume the floor-based system can be operated to maintain acceptable thermal comfort in the occupied zone of the building, while at the same time taking advantage of the temperature stratification inherent in displacement flow to achieve savings in space conditioning energy use.
AB - During recent years an increasing amount of attention has been paid to air distribution systems that individually condition the immediate environments of office workers within their workstations. As with task lighting systems, the controls for these 'task conditioning' systems are partially or entirely decentralized and under the control of the occupants. Among the primary types of task conditioning systems (floor-, desktop- and partition-based), floor-based designs are the most common, having been widely developed and used in South Africa and Europe, and are now gaining acceptance in the United States. This paper reports the results of recently completed laboratory measurements investigating the thermal performance of a floor-based task conditioning system. The experiments were performed in a controlled environment chamber configured to resemble a modern office space with modular workstation furniture and partitions. Tests were conducted to study the effects of supply volume, supply temperature, supply direction, and heat load levels in the space. In addition to detailed temperature and velocity measurements, a new skin-temperature-controlled thermal manikin was used to evaluate the non-uniform thermal environments produced by the floor-based system, in both sitting and standing positions. Under the low to intermediate supply volumes investigated in this study, the overall performance of the floor-based system resembled that of displacement ventilation systems. Primarily by controlling supply volume the floor-based system can be operated to maintain acceptable thermal comfort in the occupied zone of the building, while at the same time taking advantage of the temperature stratification inherent in displacement flow to achieve savings in space conditioning energy use.
KW - Laboratory measurements
KW - Task conditioning system
UR - http://www.scopus.com/inward/record.url?scp=0011722260&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=0011722260&partnerID=8YFLogxK
U2 - 10.1016/0378-7788(95)91161-J
DO - 10.1016/0378-7788(95)91161-J
M3 - Article
AN - SCOPUS:0011722260
SN - 0378-7788
VL - 22
SP - 173
EP - 186
JO - Energy and Buildings
JF - Energy and Buildings
IS - 3
ER -