TY - JOUR
T1 - The reliability of quantitative analysis with AES
AU - Yoshihara, K.
AU - Shimizu, R.
AU - Homma, T.
AU - Tokutaka, H.
AU - Goto, K.
AU - Fujita, D.
AU - Kurokawa, A.
AU - Ichimura, S.
AU - Kurahashi, M.
AU - Kudo, M.
AU - Hashiguchi, Y.
AU - Suzuki, T.
AU - Ohmura, T.
AU - Soeda, F.
AU - Tanaka, K.
AU - Tanaka, A.
AU - Sekine, T.
AU - Shiokawa, Y.
AU - Hayashi, T.
PY - 1990/7
Y1 - 1990/7
N2 - The Japanese VAMAS‐SCA working group is composed of 19 institutes. Three kind of AuCu alloys (Au 75 at.‐%–Cu 25 at.‐%, Au 50 at.‐%–Cu 50 at.‐%, Au 25 at.‐%–Cu 75 at.‐%) were prepared, and these specimens, pure Au and pure Cu were distributed to the members of the VAMAS‐SCA working group. The surface concentrations of these alloys were calculated from the Auger peak amplitudes in two ways. One method used the published relative sensitivity factors, and the other used pure Au and Pure Cu as the standard materials. The mean values of the surface concentrations calculated with the published relative sensitivity factors were almost the same as those calculated with the standard materials. This means that the published relative sensitivity factors are reliable to some extent. The error of the surface concentration calculated with pure Au and pure Cu as the standard materials lay between about 3% and 10%, and that with the relative sensitivity factors lay between about 7% and 20%. The calculated surface concentrations of Au were larger than the bulk concentrations of Au when the matrix effect was neglected.
AB - The Japanese VAMAS‐SCA working group is composed of 19 institutes. Three kind of AuCu alloys (Au 75 at.‐%–Cu 25 at.‐%, Au 50 at.‐%–Cu 50 at.‐%, Au 25 at.‐%–Cu 75 at.‐%) were prepared, and these specimens, pure Au and pure Cu were distributed to the members of the VAMAS‐SCA working group. The surface concentrations of these alloys were calculated from the Auger peak amplitudes in two ways. One method used the published relative sensitivity factors, and the other used pure Au and Pure Cu as the standard materials. The mean values of the surface concentrations calculated with the published relative sensitivity factors were almost the same as those calculated with the standard materials. This means that the published relative sensitivity factors are reliable to some extent. The error of the surface concentration calculated with pure Au and pure Cu as the standard materials lay between about 3% and 10%, and that with the relative sensitivity factors lay between about 7% and 20%. The calculated surface concentrations of Au were larger than the bulk concentrations of Au when the matrix effect was neglected.
UR - http://www.scopus.com/inward/record.url?scp=0025464716&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=0025464716&partnerID=8YFLogxK
U2 - 10.1002/sia.740160127
DO - 10.1002/sia.740160127
M3 - Article
AN - SCOPUS:0025464716
SN - 0142-2421
VL - 16
SP - 140
EP - 143
JO - Surface and Interface Analysis
JF - Surface and Interface Analysis
IS - 1-12