Abstract
This study considered the hydrostatic buckling failure of a noncircular composite liner with an arched invert installed in the sewer pipe. An equation was derived for the buckling of the invert liner, and its application procedure was proposed. A finite-element method was successfully employed for nonlinear and contact analyses of the buckling behaviour and the physical contact phenomena of different sewer culverts. Generally, the composite liner fails in a single-lobe buckling at the invert with the deflection similar to that observed onsite. The proposed theoretical solution was verified through numerical analysis; the critical pressure and buckling mode results showed good agreement.
Original language | English |
---|---|
Pages (from-to) | 148-157 |
Number of pages | 10 |
Journal | Thin-Walled Structures |
Volume | 102 |
DOIs | |
Publication status | Published - 2016 May 1 |
Keywords
- Arched invert
- Composite liner
- Contact analysis
- Culvertpiperenovation
- Groundwater
- Hydrostatic buckling
- Nonlinear analysis
- Theoretical solution
ASJC Scopus subject areas
- Mechanical Engineering
- Building and Construction
- Civil and Structural Engineering