既存の長屋型木造建築に施工可能な小屋裏界壁の開発

Akane Anan, Yuji Hasemi, Ken Matsuyama, Koji Kagiya, Wataru Ouchi

研究成果: Article査読

抄録

Lack of fire separation in the attic of old wooden multifamily buildings is an important cause of the rapid spread of a fire from a fire origin room to the whole building. This paper presents a design of party wall, composed of single layer of reinforced gypsum board on either side of the stud above the separation wall, suitable for existing buildings and compliant with the law on the basis of 3 series of fire tests; those reproducing fire after the penetration into the attic and ISO834 wall furnace tests with small-scale specimens and with full scale party-wall specimen.

寄稿の翻訳タイトルDevelopment of retrofit attic party wall for the prevention of rapid overall fire spread within old wooden multifamily or accommodation buildings
本文言語Japanese
ページ(範囲)435-444
ページ数10
ジャーナルJournal of Environmental Engineering (Japan)
85
772
DOI
出版ステータスPublished - 2020 6月

Keywords

  • Attic Fire Separation
  • City Fire
  • Fire Resistance Test
  • Gypsum board
  • Old Wooden Row Houses
  • Prevention of Rapid Fire spread

ASJC Scopus subject areas

  • 環境工学

フィンガープリント

「既存の長屋型木造建築に施工可能な小屋裏界壁の開発」の研究トピックを掘り下げます。これらがまとまってユニークなフィンガープリントを構成します。

引用スタイル