粉じん計に取り付ける小型サイクロン分粒装置の開発と性能評価

Toshihiko Myojo*, Takako Oyabu, Takao Tsutsui, Masaru Murata, Toshio Nagoya

*この研究の対応する著者

研究成果: Article査読

1 被引用数 (Scopus)

抄録

Dust indicators based on light scattering photometers are widely used to measure aerosol concentrations in work environments. These concentrations at workplaces in Japan are measured by these dust indicators and calibrated by mass concentration in order to control workers' exposure to dust. The mass concentration in a specific point in a workplace is measured simultaneously with a dust indicator. The mass concentration of the respirable fraction of dust particles should be determined by the gravimetric method with low volume air samplers or other devices, but some dust indicators are not equipped with a size separator for respirable fraction, and we used to get unstable results at the calibration. In this study, we designed miniature cyclones for a dust indicator and evaluated their performances of respirable fraction and PM2.5 fraction.

寄稿の翻訳タイトルDesign and evaluation of miniature cyclones for dust indicators
本文言語Japanese
ページ(範囲)425-430
ページ数6
ジャーナルJournal of UOEH
41
4
DOI
出版ステータスPublished - 2019

Keywords

  • Cyclone separator.
  • Dust indicator
  • PM
  • Respirable dust

ASJC Scopus subject areas

  • 公衆衛生学、環境および労働衛生