TY - JOUR
T1 - 360 degree selective laser trabeculoplasty in Mexican population
AU - Roberto-Lozano, Josué
AU - Kalashnikova, Mariya V.
AU - Velasco-Gallegos, Gustavo
AU - Watada, Junzo
PY - 2012/6
Y1 - 2012/6
N2 - The principal objective of the paper was to determine the safety and effectiveness of Selective Laser Trabeculoplasty (SLT) as applied to Mexican patients with Open Angle Glaucoma (OAG) according to the degree of Intraocular Pressure (IOP) reduction and the patient's required medication. We used the following materials and methods: patients with OAG who underwent 360° SLT and either were under maximum tolerated topical medical therapy or had unwanted side effects were accepted as objects. The selected patients were subject to IOP measurement with 2 different tonometry methods prior to the SLT procedure and to the follow-up measurements on the third, sixth, and twelfth month after the procedure. In order to evaluate the efficiency of the SLT procedure, statistical analysis making use of the RepeatedMeasures One-Sample t-test, Paired-Samples t-test + Pearson Correlation Coefficient test, and Wilcoxon Signed-Rank test, was implemented. The main result of our research is: the desired criteria were met by twenty seven patients, who represent a sample of 50 eyes. Based upon this data, we can conclude that the treatment with SLT applied to Mexican patients with OAG reduces IOP and the need for topical medical therapy, which can lead to better control of the disease and compliance with treatment.
AB - The principal objective of the paper was to determine the safety and effectiveness of Selective Laser Trabeculoplasty (SLT) as applied to Mexican patients with Open Angle Glaucoma (OAG) according to the degree of Intraocular Pressure (IOP) reduction and the patient's required medication. We used the following materials and methods: patients with OAG who underwent 360° SLT and either were under maximum tolerated topical medical therapy or had unwanted side effects were accepted as objects. The selected patients were subject to IOP measurement with 2 different tonometry methods prior to the SLT procedure and to the follow-up measurements on the third, sixth, and twelfth month after the procedure. In order to evaluate the efficiency of the SLT procedure, statistical analysis making use of the RepeatedMeasures One-Sample t-test, Paired-Samples t-test + Pearson Correlation Coefficient test, and Wilcoxon Signed-Rank test, was implemented. The main result of our research is: the desired criteria were met by twenty seven patients, who represent a sample of 50 eyes. Based upon this data, we can conclude that the treatment with SLT applied to Mexican patients with OAG reduces IOP and the need for topical medical therapy, which can lead to better control of the disease and compliance with treatment.
KW - Open angle glaucoma
KW - Selective laser trabeculoplasty
KW - Statistical analysis
UR - http://www.scopus.com/inward/record.url?scp=84865011318&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=84865011318&partnerID=8YFLogxK
M3 - Article
AN - SCOPUS:84865011318
SN - 1343-0130
VL - 16
SP - 540
EP - 546
JO - Journal of Advanced Computational Intelligence and Intelligent Informatics
JF - Journal of Advanced Computational Intelligence and Intelligent Informatics
IS - 4
ER -