TY - JOUR
T1 - Active microdroplet merging by hydrodynamic flow control using a pneumatic actuator-assisted pillar structure
AU - Yoon, Dong Hyun
AU - Jamshaid, Afshan
AU - Ito, Junichi
AU - Nakahara, Asahi
AU - Tanaka, Daiki
AU - Akitsu, Takashiro
AU - Sekiguchi, Tetsushi
AU - Shoji, Shuichi
PY - 2014/8/21
Y1 - 2014/8/21
N2 - This paper describes a microdroplet merging device that can actively control the merging of various droplets under a wide range of flow conditions, using a simple structure. The microdroplets were trapped and merged in a wide chamber divided by pillars, and their behavior was controlled by two horizontal pneumatic microactuators. Hydrodynamic flow control by the actuation was evaluated numerically, and the trapping and merging of droplets were achieved experimentally and controlled via pressure applied to the microactuators. Furthermore, two independently generated droplets were merged under four different modes, ranging from no merging to four-droplet merging, with different ratios and volumes. The pneumatic actuators allowed not only the control of the number of merged droplets, but also a wide range of applied droplet volumes. The device was fabricated simply using a single-layer PDMS (polydimethylsiloxane) structure, and the continuous merging performance operated using only hydrodynamic flow control without any surfactant. Finally, chemical synthesis of a metal complex was performed by the droplet merging method. Crystallization of the complex was visualized in real time, and the synthesis was verified by ultraviolet-visible spectroscopy.
AB - This paper describes a microdroplet merging device that can actively control the merging of various droplets under a wide range of flow conditions, using a simple structure. The microdroplets were trapped and merged in a wide chamber divided by pillars, and their behavior was controlled by two horizontal pneumatic microactuators. Hydrodynamic flow control by the actuation was evaluated numerically, and the trapping and merging of droplets were achieved experimentally and controlled via pressure applied to the microactuators. Furthermore, two independently generated droplets were merged under four different modes, ranging from no merging to four-droplet merging, with different ratios and volumes. The pneumatic actuators allowed not only the control of the number of merged droplets, but also a wide range of applied droplet volumes. The device was fabricated simply using a single-layer PDMS (polydimethylsiloxane) structure, and the continuous merging performance operated using only hydrodynamic flow control without any surfactant. Finally, chemical synthesis of a metal complex was performed by the droplet merging method. Crystallization of the complex was visualized in real time, and the synthesis was verified by ultraviolet-visible spectroscopy.
UR - http://www.scopus.com/inward/record.url?scp=84904346122&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=84904346122&partnerID=8YFLogxK
U2 - 10.1039/c4lc00378k
DO - 10.1039/c4lc00378k
M3 - Article
C2 - 24961178
AN - SCOPUS:84904346122
SN - 1473-0197
VL - 14
SP - 3050
EP - 3055
JO - Lab on a Chip - Miniaturisation for Chemistry and Biology
JF - Lab on a Chip - Miniaturisation for Chemistry and Biology
IS - 16
ER -