Amperometric sensing of H2O2 and glucose using wet-chemically deposited MnO2 thin films

Terukazu Kondo, Yuta Matsushima, Keigo Matsuda, Hidero Unuma*

*この研究の対応する著者

研究成果: Article査読

3 被引用数 (Scopus)

抄録

Herein, we report that -MnO2 thin films wet-chemically deposited on electro-conductive substrates exhibited good sensing abilities toward hydrogen peroxide and glucose without the assistance of immobilized enzymes, as well as the excellent supercapacitic performance described in our previous paper. High-sensitivity values of 380mA/(M·cm2) (H2O2) and 300mA/(M·cm2) (glucose) were attained with low detection limits of 0.7-mol/dm3 (H2O2) and 0.6-mol/dm3 (glucose). The good sensitivities and low detection limits were attributed to the large surface area of accumulated MnO2 nanosheets and their firm adhesion to the substrates. The method presented herein can be used for facile film deposition with good controllability and reproducibility.

本文言語English
ページ(範囲)260-262
ページ数3
ジャーナルJournal of the Ceramic Society of Japan
126
4
DOI
出版ステータスPublished - 2018 4月
外部発表はい

ASJC Scopus subject areas

  • セラミックおよび複合材料
  • 化学 (全般)
  • 凝縮系物理学