An alpha-particle imaging system for detecting plutonium contamination

Takao Iida*, Seiichi Yamamoto, Yukimasa Ikebe, Akio Seki, Kei Nakata, Minoru Ebana, Masashi Kanamori, Mamoru Yoshida

*この研究の対応する著者

研究成果: Article査読

21 被引用数 (Scopus)

抄録

A new type of alpha-particle imaging system was constructed to reduce the time required for detecting plutonium contamination. The imaging system consists of a ZnS(Ag) screen, two tapered fibers, an image intensifier, and Polaroid film. Spots due to single alpha-particles can easily be obtained on the Polaroid film. The observed spatial resolution is more than 3 lp/mm. This system requires about one-seventh of the exposure time required by ZnS(Ag) autoradiography in order to distinguish between plutonium contamination and radon and thoron daughter products.

本文言語English
ページ(範囲)413-418
ページ数6
ジャーナルNuclear Instruments and Methods In Physics Research
212
1-3
DOI
出版ステータスPublished - 1983 7月 1
外部発表はい

ASJC Scopus subject areas