TY - JOUR
T1 - An application of the advanced high-accuracy universal polarimeter to the chiroptical measurement of an intercalated compound K 4Nb 6O 17 with high anisotropy
AU - Tanaka, Masahito
AU - Nakamura, Naomichi
AU - Koshima, Hideko
AU - Asahi, Toru
PY - 2012/5/2
Y1 - 2012/5/2
N2 - The advanced high-accuracy universal polarimeter (HAUP) method was applied to observe anisotropic and chiroptical properties of an intercalated azobenzene derivative compound into K 4Nb 6O 17 crystals. Prior to the HAUP measurement of the intercalated compound, we extended the HAUP method employing a conventional light source system composed of Xe or D 2 lamps and a monochromator instead of a laser system. The performance of the advanced HAUP system was evaluated and we determined the parasitic ellipticities of the cross polarizers, which are essential for obtaining accurate values. The optical system was applicable to simultaneously measure the linear dichroism (LD), circular dichroism (CD), linear birefringence (LB) and circular birefringence (CB) spectra of an intercalated compound in the ultraviolet and visible regions. We found the KramersKronig relation between CB and CD as well as in the case of LB and LD. Changes in LB and LD signals as obtained from HAUP measurements originated from the molecular orientation of guest molecules by the intercalation. Moreover, CB and CD signals indicated the appearance of induced chirality in the intercalated azobenzene derivative compound. These results demonstrated the usefulness of the HAUP system for evaluating the molecular conformation of chiral anisotropic specimens.
AB - The advanced high-accuracy universal polarimeter (HAUP) method was applied to observe anisotropic and chiroptical properties of an intercalated azobenzene derivative compound into K 4Nb 6O 17 crystals. Prior to the HAUP measurement of the intercalated compound, we extended the HAUP method employing a conventional light source system composed of Xe or D 2 lamps and a monochromator instead of a laser system. The performance of the advanced HAUP system was evaluated and we determined the parasitic ellipticities of the cross polarizers, which are essential for obtaining accurate values. The optical system was applicable to simultaneously measure the linear dichroism (LD), circular dichroism (CD), linear birefringence (LB) and circular birefringence (CB) spectra of an intercalated compound in the ultraviolet and visible regions. We found the KramersKronig relation between CB and CD as well as in the case of LB and LD. Changes in LB and LD signals as obtained from HAUP measurements originated from the molecular orientation of guest molecules by the intercalation. Moreover, CB and CD signals indicated the appearance of induced chirality in the intercalated azobenzene derivative compound. These results demonstrated the usefulness of the HAUP system for evaluating the molecular conformation of chiral anisotropic specimens.
UR - http://www.scopus.com/inward/record.url?scp=84859786392&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=84859786392&partnerID=8YFLogxK
U2 - 10.1088/0022-3727/45/17/175303
DO - 10.1088/0022-3727/45/17/175303
M3 - Article
AN - SCOPUS:84859786392
SN - 0022-3727
VL - 45
JO - Journal Physics D: Applied Physics
JF - Journal Physics D: Applied Physics
IS - 17
M1 - 175303
ER -