T1 - An ultrahigh vacuum chamber for simultaneous Fourier transform infrared spectroscopy and microgravimetric measurements
AU - Zhuang, Guorong
AU - Chottiner, Gary
AU - Bae, In Tae
AU - Hwang, Euijin
AU - Scherson, Daniel Alberto
PY - 1994/12/1
Y1 - 1994/12/1
N2 - A small UHV chamber that fits in the sample compartment of a commercial Fourier transform infrared spectrometer (IBM-98, Brucker) has been designed and constructed to acquire reflection/absorption spectra of species adsorbed and/or condensed on metal films vapor deposited in situ on the surface of a quartz-crystal microbalance (QCM). The QCM is mounted on a variable-temperature Au-plated Cu block, which houses a second (reference) QCM, attached in turn to a liquid-He cold finger. The unique capabilities of this apparatus make it possible to correlate quantitatively various spectral characteristics, including peak widths and intensities, with the absolute mass of adsorbed and/or condensed material per unit area m, or coverage, over a wide range of m and temperatures. Results obtained using tetrahydrofuran (THF) condensed on freshly vapor deposited gold films have shown that the sensitivity of the instrument is sufficient to detect mTHF on the order of a single monolayer. Plots of the intensity of the most prominent THF peak at 1064 cm-1 as a function of mTHF were found to deviate significantly from linearity in the range 0.1THF<2.8 μg/cm2. In addition, the relative intensities of the most prominent THF peaks for even the largest mTHF examined differed markedly from those of bulk-like THF, an effect that can be attributed to a preferential orientation of THF microcrystals with respect to the underlying substrate. In the case of coverages on the order of one monolayer, such spectral behavior may arise from specific adsorbate/substrate interactions, which can cause a lowering in the molecular symmetry and/or distortions in the structure of the adsorbate. Evidence in support of a Au-induced THF activation was obtained from independent temperature programmed desorption (TPD) measurements involving perdeuterated THF (TDF) performed in a separate UHV system. In particular, for exposures of about 1.5 L, the TPD spectra for the largest m/e features, i.e., 80, 48, and 30, revealed the presence of a peak centered at a higher temperature (∼180 K) than that found for much larger exposures (120 K).
AB - A small UHV chamber that fits in the sample compartment of a commercial Fourier transform infrared spectrometer (IBM-98, Brucker) has been designed and constructed to acquire reflection/absorption spectra of species adsorbed and/or condensed on metal films vapor deposited in situ on the surface of a quartz-crystal microbalance (QCM). The QCM is mounted on a variable-temperature Au-plated Cu block, which houses a second (reference) QCM, attached in turn to a liquid-He cold finger. The unique capabilities of this apparatus make it possible to correlate quantitatively various spectral characteristics, including peak widths and intensities, with the absolute mass of adsorbed and/or condensed material per unit area m, or coverage, over a wide range of m and temperatures. Results obtained using tetrahydrofuran (THF) condensed on freshly vapor deposited gold films have shown that the sensitivity of the instrument is sufficient to detect mTHF on the order of a single monolayer. Plots of the intensity of the most prominent THF peak at 1064 cm-1 as a function of mTHF were found to deviate significantly from linearity in the range 0.1THF<2.8 μg/cm2. In addition, the relative intensities of the most prominent THF peaks for even the largest mTHF examined differed markedly from those of bulk-like THF, an effect that can be attributed to a preferential orientation of THF microcrystals with respect to the underlying substrate. In the case of coverages on the order of one monolayer, such spectral behavior may arise from specific adsorbate/substrate interactions, which can cause a lowering in the molecular symmetry and/or distortions in the structure of the adsorbate. Evidence in support of a Au-induced THF activation was obtained from independent temperature programmed desorption (TPD) measurements involving perdeuterated THF (TDF) performed in a separate UHV system. In particular, for exposures of about 1.5 L, the TPD spectra for the largest m/e features, i.e., 80, 48, and 30, revealed the presence of a peak centered at a higher temperature (∼180 K) than that found for much larger exposures (120 K).
UR - http://www.scopus.com/inward/record.url?scp=0028493419&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=0028493419&partnerID=8YFLogxK
U2 - 10.1063/1.1144640
DO - 10.1063/1.1144640
M3 - Article
AN - SCOPUS:0028493419
SN - 0034-6748
VL - 65
SP - 2494
EP - 2499
JO - Review of Scientific Instruments
JF - Review of Scientific Instruments
IS - 8
ER -