抄録
An artificial neural network (ANN) for predicting critical heat flux (CHF) of concentric-tube open thermosyphon has been trained successfully based on the experimental data from the literature. The dimensionless input parameters of the ANN are density ratio, ρl/ρv, the ratio of the heated tube length to the inner diameter of the outer tube L/Di, the ratio of frictional area, di/(Di + do), and the ratio of equivalent heated diameter to characteristic bubble size, D he/[σ/g(ρl-ρv)]0.5, the output is Kutateladze number, Ku. The predicted values of ANN are found to be in reasonable agreement with the actual values from the experiments with a mean relative error (MRE) of 8.46%. For a particular outer tube, the CHF increases initially and then decreases with increasing inner tube diameter, and has a maximum at an optimum diameter of inner tube (do,opt). The do,opt is correlated with the working fluid and may decrease with the increase of ρl/ρv. CHF decreases with the increase of L/Di, and the decreasing rate decreases as L/D i increases. In the influence scope of pressure, the CHF decreases with increasing pressure for R22, while increases with increasing pressure for R113.
本文言語 | English |
---|---|
ホスト出版物のタイトル | International Conference on Nuclear Engineering, Proceedings, ICONE |
ページ | 689-696 |
ページ数 | 8 |
巻 | 4 |
版 | PARTS A AND B |
DOI | |
出版ステータス | Published - 2010 |
イベント | 18th International Conference on Nuclear Engineering, ICONE18 - Xi'an 継続期間: 2010 5月 17 → 2010 5月 21 |
Other
Other | 18th International Conference on Nuclear Engineering, ICONE18 |
---|---|
City | Xi'an |
Period | 10/5/17 → 10/5/21 |
ASJC Scopus subject areas
- 原子力エネルギーおよび原子力工学