N1 - Funding Information:
This research was conducted under a cooperative research arrangement between the U.S. Department of Transportation, National Highway Traffic Safety Administration, and the Ministry of Land, Infrastructure and Transport of Japan, Road Transport Bureau.
PY - 2003/6
Y1 - 2003/6
N2 - There is little known data characterizing the biomechanical responses of the human head and neck under direct head loading conditions. However, the evaluation of the appropriateness of current crash test dummy head-neck systems is easily accomplished. Such an effort, using experimental means, generates and provides characterizations of human head-neck response to several direct head loading conditions. Low-level impact loads were applied to the head and face of volunteers and dummies. The resultant forces and moments at the occipital condyle were calculated. For the volunteers, activation of the neck musculature was determined using electromyography (EMG). In addition, cervical vertebral motions of the volunteers have been taken by means of X-ray cineradiography. The Ethics Committee of Tsukuba University approved the protocol of the experiments in advance. External force of about 210 N was applied to the head and face of five volunteers with an average age of 25 for the duration of 100 msec or so, via a strap at one of four locations in various directions: (1) an upward load applied to the chin, (2) a rearward load applied to the chin without facial mask, (3) a rearward load applied to the chin with the facial mask, and (4) a rearward load applied to the forehead. The same impact force as those for the human volunteers was also applied to HY-III, THOR, and BioRID. We found that cervical vertebral motions differ markedly according to the difference in impact loading condition. Some particular characteristics are also found, such as the flexion or extension of the upper cervical vertebrae (C0, C1, and C2) or middle cervical vertebrae (C3-C4), showing that the modes of cervical vertebral motions are markedly different among the different loading conditions. We also found that the biofidelity of dummies to neck response characteristics of the volunteers at the low-level impact loads is in the order of BioRID, THOR, and HY-III. It is relevant in this regard that the BioRID dummy was designed for a low-severity impact environment, whereas THOR and HY-III were optimized for higher-severity impacts.
AB - There is little known data characterizing the biomechanical responses of the human head and neck under direct head loading conditions. However, the evaluation of the appropriateness of current crash test dummy head-neck systems is easily accomplished. Such an effort, using experimental means, generates and provides characterizations of human head-neck response to several direct head loading conditions. Low-level impact loads were applied to the head and face of volunteers and dummies. The resultant forces and moments at the occipital condyle were calculated. For the volunteers, activation of the neck musculature was determined using electromyography (EMG). In addition, cervical vertebral motions of the volunteers have been taken by means of X-ray cineradiography. The Ethics Committee of Tsukuba University approved the protocol of the experiments in advance. External force of about 210 N was applied to the head and face of five volunteers with an average age of 25 for the duration of 100 msec or so, via a strap at one of four locations in various directions: (1) an upward load applied to the chin, (2) a rearward load applied to the chin without facial mask, (3) a rearward load applied to the chin with the facial mask, and (4) a rearward load applied to the forehead. The same impact force as those for the human volunteers was also applied to HY-III, THOR, and BioRID. We found that cervical vertebral motions differ markedly according to the difference in impact loading condition. Some particular characteristics are also found, such as the flexion or extension of the upper cervical vertebrae (C0, C1, and C2) or middle cervical vertebrae (C3-C4), showing that the modes of cervical vertebral motions are markedly different among the different loading conditions. We also found that the biofidelity of dummies to neck response characteristics of the volunteers at the low-level impact loads is in the order of BioRID, THOR, and HY-III. It is relevant in this regard that the BioRID dummy was designed for a low-severity impact environment, whereas THOR and HY-III were optimized for higher-severity impacts.
KW - Biofidelity
KW - Cervical Vertebrae
KW - Cineradiography
KW - Dummy
KW - Human Volunteer
KW - Neck
UR - http://www.scopus.com/inward/record.url?scp=0038445144&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=0038445144&partnerID=8YFLogxK
U2 - 10.1080/15389580309861
DO - 10.1080/15389580309861
M3 - Article
C2 - 16210199
AN - SCOPUS:0038445144
SN - 1538-9588
VL - 4
SP - 141
EP - 152
JO - Traffic Injury Prevention
JF - Traffic Injury Prevention
IS - 2
ER -