抄録
The unsteady inner flow structure of a single-stage axial flow compressor under the coexisting conditions of surge and rotating stall was experimentally investigated via detailed measurements of the unsteady characteristics and the internal flow velocity fluctuations. The main relevant feature of the tested compressor is a shock tube with a capacity tank connected in series to the compressor outlet through slits and a concentric duplex pipe: surge and rotating stall can both be generated by connecting the shock tube. Research attention is focused on the unsteady behavior of a rotating stall during the surge cycle. The size of the rotating stall cell during the recovery process of an irregular surge cycle was experimentally determined by the circumferential flow velocity fluctuations ahead of the rotor blade. The results suggested that the size of the rotating stall cell at the switching point of the performance curve between large and small cycles is considered to be the key parameter in determining the following surge cycle. In addition, the surge cycle is largely influenced by the unsteady behavior of the rotating stall cell.
本文言語 | English |
---|---|
ページ(範囲) | 547-554 |
ページ数 | 8 |
ジャーナル | Journal of Thermal Science |
巻 | 22 |
号 | 6 |
DOI | |
出版ステータス | Published - 2013 12月 |