TY - JOUR
T1 - Construction of electrochemical flow immunoassay system using capillary columns and ferrocene conjugated immunoglobulin G for detection of human chorionic gonadotrophin
AU - Lim, Tae Kyu
AU - Matsunaga, Tadashi
PY - 2001
Y1 - 2001
N2 - In this paper is reported a miniaturized flow immunoassay system. Ferrocenecarboxylic acid (Fc) conjugated with anti-HCG immunoglobulin G (IgG) antibody (Fc-IgG) was prepared, and used as a novel analytical reagent. The system consists of the immunoreaction section, the capillary column packed with cation exchange resin, and the flow cell for electrochemical detection of Fc-IgG. Antibody-antigen complexes were separated from their free conjugate on the basis of differences in isoelectric point (pI) using a cation exchange capillary column. The assay yielded a linear relationship between signal and HCG concentration in the range 0-2000 mIU/ml. This simple technique enables the assay of HCG within 2 min. The cation exchange capillary column was regenerated by occasional elution with malonate buffer (pH 6.0) containing 0.5 M NaCl, to remove free conjugate. Free conjugate recovered in this manner could be reused up to eight times without significant decreases in the sensitivity of the immunoassay. This electrochemical flow immunoassay requires only minute quantities of serum and generates highly reproducible results.
AB - In this paper is reported a miniaturized flow immunoassay system. Ferrocenecarboxylic acid (Fc) conjugated with anti-HCG immunoglobulin G (IgG) antibody (Fc-IgG) was prepared, and used as a novel analytical reagent. The system consists of the immunoreaction section, the capillary column packed with cation exchange resin, and the flow cell for electrochemical detection of Fc-IgG. Antibody-antigen complexes were separated from their free conjugate on the basis of differences in isoelectric point (pI) using a cation exchange capillary column. The assay yielded a linear relationship between signal and HCG concentration in the range 0-2000 mIU/ml. This simple technique enables the assay of HCG within 2 min. The cation exchange capillary column was regenerated by occasional elution with malonate buffer (pH 6.0) containing 0.5 M NaCl, to remove free conjugate. Free conjugate recovered in this manner could be reused up to eight times without significant decreases in the sensitivity of the immunoassay. This electrochemical flow immunoassay requires only minute quantities of serum and generates highly reproducible results.
KW - Electrochemical flow immunoassay
KW - Fc-IgG
KW - Miniaturized flow immunoassay system
UR - http://www.scopus.com/inward/record.url?scp=0034777252&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=0034777252&partnerID=8YFLogxK
U2 - 10.1016/S0956-5663(01)00228-7
DO - 10.1016/S0956-5663(01)00228-7
M3 - Article
C2 - 11679290
AN - SCOPUS:0034777252
SN - 0956-5663
VL - 16
SP - 1063
EP - 1069
JO - Biosensors and Bioelectronics
JF - Biosensors and Bioelectronics
IS - 9-12
ER -