Development and validation of static simulation model for CO2 heat pump

Seiichi Yamaguchi*, Daisuke Kato, Kiyoshi Saito, Sunao Kawai

*この研究の対応する著者

研究成果: Article査読

41 被引用数 (Scopus)

抄録

A simulation model for the CO2 heat pump water heater was developed and validated in this study. Component models of the gas cooler, evaporator, compressor, and expansion valve were constructed with careful consideration for the heat transfer performances. To validate the simulation model, experiments were carried out using an actual CO2 heat pump water heater (water heating capacity: 22.3 kW; hot-water temperature: 90 °C). In simulations and experiments, the effects of the inlet water temperature and outside air temperature on the system characteristics were discussed. As a result, the average difference in COP between the simulation results and experimental results is 1.5%.

本文言語English
ページ(範囲)1896-1906
ページ数11
ジャーナルInternational Journal of Heat and Mass Transfer
54
9-10
DOI
出版ステータスPublished - 2011 4月

ASJC Scopus subject areas

  • 凝縮系物理学
  • 機械工学
  • 流体および伝熱

フィンガープリント

「Development and validation of static simulation model for CO2 heat pump」の研究トピックを掘り下げます。これらがまとまってユニークなフィンガープリントを構成します。

引用スタイル