Development of a pixel detector for ultra-cold neutrons

S. Kawasaki*, G. Ichikawa, M. Hino, Y. Kamiya, M. Kitaguchi, S. Komamiya, T. Sanuki, S. Sonoda

*この研究の対応する著者

研究成果: Article査読

13 被引用数 (Scopus)

抄録

A pixel detector with high spatial resolution and temporal information for ultra-cold neutrons is developed based on a commercial CCD on which a neutron converter is attached. 10B and 6Li are tested for the neutron converter and 10B is found to be more suitable based on efficiency and spatial resolution. The pixel detector has an efficiency of 44.1 ± 1.1 % and a spatial resolution of 2.9 ± 0.1 μ m (1 sigma).

本文言語English
ページ(範囲)42-47
ページ数6
ジャーナルNuclear Instruments and Methods in Physics Research, Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
615
1
DOI
出版ステータスPublished - 2010 3月 21