抄録
A 30 m prototype 100 MVA (66 kV-1 kA) high temperature superconducting (HTSC) power cable system was developed. This system consists of a 30 m long single phase cable, terminations, a 66 kV XLPE cable for a current loop and a cooling system which circulated sub-cooled liquid nitrogen. In initial tests, 40 kV-1 kA ac was successfully applied to the HTSC prototype cable. As the next step, 40 kV-500 A ac was successfully applied for more than 100 hours. During the test, the temperature and pressure of circulating liquid nitrogen were controlled to 72 K and 0.2 kg/cm2, respectively.
本文言語 | English |
---|---|
ページ | 529-532 |
ページ数 | 4 |
出版ステータス | Published - 1999 |
外部発表 | はい |
イベント | Proceedings of the 1999 13th IEEE International Conference on Dielectric Liquids (ICDL '99) - Nara, Jpn 継続期間: 1999 7月 20 → 1999 7月 25 |
Other
Other | Proceedings of the 1999 13th IEEE International Conference on Dielectric Liquids (ICDL '99) |
---|---|
City | Nara, Jpn |
Period | 99/7/20 → 99/7/25 |
ASJC Scopus subject areas
- 材料科学(全般)
- 工学(全般)