In recent years, due to the increasing rate of elderly people in Japan, the needs to detect adults' diseases at the early stage becomes a high priority. In particular, an increased interest in detecting heart and cerebrovascular diseases at an early stage may allow clinicians to begin treatment sooner (when more treatment options are available), when interventions are generally more effective and less expensive. For this purpose, the introduction of robotic-assisted technology has advantages in terms of repetitiveness and accuracy of the measurement procedure. Therefore, at Waseda University, we have proposed the development of a carotid blood flow measurement system to support doctors while using ultrasound diagnostic equipments to detect arteriosclerosis and myocardial ischemia by measuring wave intensity. In this paper, the Waseda-Tokyo Women's Medical-Aloka Blood Flow Measurement System No. 1 Refined II (WTA-1RII) is detailed. The WTA-1RII is composed by an ultrasound diagnostic system and a probe-supporting robotic device. The robotic device is composed by a parallel link manipulator (for fine adjustment) and a passive arm (for rough positioning). The WTA-1RII has improved the design of the gravity compensation mechanism (composed by a constant force spring attached to a slide guide). In addition, a genetic algorithm has been implemented to determine the optimal link's position of the 6-DOF parallel manipulator to increase the workspace. Finally, a set of experiments were carried out to determine the usability of the proposed system.

本文言語English
ホスト出版物のタイトル2009 IEEE/ASME International Conference on Advanced Intelligent Mechatronics, AIM 2009
ページ717-722
ページ数6
DOI
出版ステータスPublished - 2009 11月 4
イベント2009 IEEE/ASME International Conference on Advanced Intelligent Mechatronics, AIM 2009 - Singapore, Singapore
継続期間: 2009 7月 142009 7月 17

出版物シリーズ

名前IEEE/ASME International Conference on Advanced Intelligent Mechatronics, AIM

Conference

Conference2009 IEEE/ASME International Conference on Advanced Intelligent Mechatronics, AIM 2009
国/地域Singapore
CitySingapore
Period09/7/1409/7/17

ASJC Scopus subject areas

  • 制御およびシステム工学
  • ソフトウェア
  • コンピュータ サイエンスの応用
  • 電子工学および電気工学

フィンガープリント

「Development of a robotic carotid blood measurement WTA-1RII: Mechanical improvement of gravity compensation mechanism and optimal link position of the parallel manipulator based on GA」の研究トピックを掘り下げます。これらがまとまってユニークなフィンガープリントを構成します。

引用スタイル