TY - JOUR
T1 - Development of an underground radon detector using an optical fiber
AU - Yamamoto, S.
AU - Yoshida, Y.
AU - Iida, T.
N1 - Funding Information:
Manuscript received November 20, 2002; revised March 29, 2003. This work was supported in part by the Japan Science and Technology (JST) Corporation. S. Yamamoto and Y. Yoshida are with the Kobe City College of Technology, Nishi-ku, Kobe 651-2194, Japan (e-mail: s-yama@kobe-kosen.ac.jp). T. Iida is with the Nagoya University, Chikusa-ku, Nagoya 464-8063, Japan. Digital Object Identifier 10.1109/TNS.2003.814542 Fig. 1. Schematic drawing of the proposed underground radon detector using an optical fiber.
PY - 2003/8
Y1 - 2003/8
N2 - We developed and tested a new underground radon detector using an optical fiber. Previous underground radon detectors used a small-diameter photo-multiplier tube (PMT) behind the chamber, thus, the diameter of the underground radon detector was determined by the size of the PMT. The larger diameter of the detector resulted in considerable labor for drilling holes into soil. The new underground radon detector consists of a small chamber, an optical fiber, and a PMT. The small chamber is a scintillation detector using a ZnS(Ag) film. The optical fiber transfers the scintillated light produced in the chamber to the PMT that is positioned above the soil. In this configuration, the size of the detector was not determined by the size of the PMT. The diameter of the optical fiber used was 5 mm and the outside diameter of the detector was reduced to be 12 mm. Although the light lost from the optical fiber was about 90%, the level of the scintillation signal was much higher than the noise level produced by the PMT and electronics. Measuring the performance of the underground radon detector, we found that the energy response had a clear distribution due to alpha particles emitted by radon and its decay products. The temporal response of the detector was approximately 2 h. Sensitivity was approximately 0.01 counts/h/Bq/m3, one third of the previous underground radon detector. These results indicate the developed radon detector can be used for continuous measurements of radon concentration in underground soil with easy handling.
AB - We developed and tested a new underground radon detector using an optical fiber. Previous underground radon detectors used a small-diameter photo-multiplier tube (PMT) behind the chamber, thus, the diameter of the underground radon detector was determined by the size of the PMT. The larger diameter of the detector resulted in considerable labor for drilling holes into soil. The new underground radon detector consists of a small chamber, an optical fiber, and a PMT. The small chamber is a scintillation detector using a ZnS(Ag) film. The optical fiber transfers the scintillated light produced in the chamber to the PMT that is positioned above the soil. In this configuration, the size of the detector was not determined by the size of the PMT. The diameter of the optical fiber used was 5 mm and the outside diameter of the detector was reduced to be 12 mm. Although the light lost from the optical fiber was about 90%, the level of the scintillation signal was much higher than the noise level produced by the PMT and electronics. Measuring the performance of the underground radon detector, we found that the energy response had a clear distribution due to alpha particles emitted by radon and its decay products. The temporal response of the detector was approximately 2 h. Sensitivity was approximately 0.01 counts/h/Bq/m3, one third of the previous underground radon detector. These results indicate the developed radon detector can be used for continuous measurements of radon concentration in underground soil with easy handling.
KW - Optical fiber
KW - Radon
KW - Underground
UR - http://www.scopus.com/inward/record.url?scp=0042928132&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=0042928132&partnerID=8YFLogxK
U2 - 10.1109/TNS.2003.814542
DO - 10.1109/TNS.2003.814542
M3 - Article
AN - SCOPUS:0042928132
SN - 0018-9499
VL - 50
SP - 987
EP - 990
JO - IEEE Transactions on Nuclear Science
JF - IEEE Transactions on Nuclear Science
IS - 4 II
ER -