TY - JOUR
T1 - Development of prototype PET scanner using dual-sided readout DOI-PET modules
AU - Fujita, T.
AU - Kataoka, J.
AU - Kishimoto, A.
AU - Kurei, Y.
AU - Nishiyama, T.
AU - Ohshima, T.
AU - Taya, T.
N1 - Publisher Copyright:
© 2014 IOP Publishing Ltd and Sissa Medialab srl.
PY - 2014/12/17
Y1 - 2014/12/17
N2 - In our previous work, we proposed a novel design for a gamma-ray detector module capable of measuring the depth of interaction (DOI). In this paper, we further developed DOI-PET detector modules and a data acquisition system, and evaluated its performance. Each detector module was composed of a 3-D scintillator array and two large-area monolithic Multi-Pixel Photon Counter (MPPC) arrays coupled to both ends of the 3-D scintillator array, leading to only 8-ch signal outputs from a module. The 3-D scintillator array was composed of 9× 9 ×7 matrices of 1.0×1.0×3.0 mm3 Ce:GAGG crystals. The detector module showed good energy resolution of 10.6% as measured at 511 keV and a high average peak to valley ratio higher than 8 for each pixel crystal identified in the X-Y-Z directions. Moreover, we evaluated the spatial resolution of a virtual 18-ch PET gantry simulated by using two detector modules that were flexibly controlled using both the X-stage and θ-stage in 20-degree steps. By measuring a 22Na point source (0.25 mm in diameter), we showed that spatial resolution substantially degrades from 1.0 mm to 7.8 mm (FWHM; as measured at 0 mm and 28 mm off-center) with a non-DOI configuration, whereas the corresponding values for the DOI configuration were 0.9 mm and 1.5 mm, respectively (FWHM; as measured at 0 mm and 28 mm off-center). This preliminary study confirms that our DOI-PET module is useful for future high spatial resolution and compact small-animal PET scanners without radial image distortions at the peripheral regions of the field of view (FOV).
AB - In our previous work, we proposed a novel design for a gamma-ray detector module capable of measuring the depth of interaction (DOI). In this paper, we further developed DOI-PET detector modules and a data acquisition system, and evaluated its performance. Each detector module was composed of a 3-D scintillator array and two large-area monolithic Multi-Pixel Photon Counter (MPPC) arrays coupled to both ends of the 3-D scintillator array, leading to only 8-ch signal outputs from a module. The 3-D scintillator array was composed of 9× 9 ×7 matrices of 1.0×1.0×3.0 mm3 Ce:GAGG crystals. The detector module showed good energy resolution of 10.6% as measured at 511 keV and a high average peak to valley ratio higher than 8 for each pixel crystal identified in the X-Y-Z directions. Moreover, we evaluated the spatial resolution of a virtual 18-ch PET gantry simulated by using two detector modules that were flexibly controlled using both the X-stage and θ-stage in 20-degree steps. By measuring a 22Na point source (0.25 mm in diameter), we showed that spatial resolution substantially degrades from 1.0 mm to 7.8 mm (FWHM; as measured at 0 mm and 28 mm off-center) with a non-DOI configuration, whereas the corresponding values for the DOI configuration were 0.9 mm and 1.5 mm, respectively (FWHM; as measured at 0 mm and 28 mm off-center). This preliminary study confirms that our DOI-PET module is useful for future high spatial resolution and compact small-animal PET scanners without radial image distortions at the peripheral regions of the field of view (FOV).
KW - Gamma camera, SPECT, PET PET/CT, coronary CT angiography (CTA)
KW - Photon detectors for UV, visible and IR photons (solid-state) (PIN diodes, APDs, Si-PMTs, G-APDs, CCDs, EBCCDs, EMCCDs etc)
UR - http://www.scopus.com/inward/record.url?scp=84950310843&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=84950310843&partnerID=8YFLogxK
U2 - 10.1088/1748-0221/9/12/P12015
DO - 10.1088/1748-0221/9/12/P12015
M3 - Article
AN - SCOPUS:84950310843
SN - 1748-0221
VL - 9
JO - Journal of Instrumentation
JF - Journal of Instrumentation
IS - 12
M1 - P12015
ER -