DEVELOPMENT OF TRANSPIRATION-MASS SPECTROMETRY SYSTEM AND ITS APPLICATION TO MEASUREMENT OF ZINC VAPOUR PRESSURE.

Akio Fuwa*, Kenji Sugawara, Eiichi Kato

*この研究の対応する著者

    研究成果: Article査読

    1 被引用数 (Scopus)

    抄録

    For analysis in high temperature metallurgical processes involving gaseous species, a combination system of a transpiration reactor and mass spectrometry has been constructed. After obtaining the mass separation factor at nozzle-skimmer orifices, the vapor pressure has been measured. The vapor pressure obtained is in good agreement with literature values: Log (P//Z//n left bracket Pa right bracket ) equals minus 7. 47 multiplied by 10**3 multiplied by T** minus **1 plus 11. 40 (910 K less than T less than 1000 K).