TY - GEN
T1 - Digital fabrication of 3D bio devices utilizing PELID (Patterning with Electrostatically-Injected Droplet) method
AU - Umezu, Shinjiro
AU - Hatta, Tatsuru
AU - Ohmori, Hitoshi
PY - 2012/12/1
Y1 - 2012/12/1
N2 - In this paper, we fabricated soft 3D bio devices utilizing PELID (Patterning with Electrostatically-Injected Droplet) method. It is preferable to perform laboratory experiments with 3D structures in bioengineering. We have investigated mechanism and fundamental characteristics of the PELID method and now been applying for new printing technology of high image quality and 3D printing technology. The method has two merits, higher resolution than commercial printer and ability to eject with highly viscous liquid. We can eject viscous paste that viscosity is 30000 mPas. At DF 2010, I already presented that cells and scaffolds were printed to fabricate 3D cell structures because scaffolds assisted the weight of cells. Now, we should fabricate 3D structure that has cave because real 3D structure has blood vessel like cave. It is difficult to fabricate 3D structure that has cave. Gelatin is used as sacrificial layer. When the printed 3D structure is put into hot water, gelatin is removed. With this technique, we can print 3D structure that has cave. The tube filled with the liquid that contained gelatin and the tube filled with the liquid that contained calcium alginate was hanged down perpendicular to a dish. Voltage was applied between the syringes and the dish by power supplies (voltage range: -5kV ∼ +5kV, Matsusada Precision Inc, Tokyo, HVR-10P). The air gap was adjusted by a z-stage and the plate electrode was moved in x and y directions with two linear motors. PC controlled voltage application and motion of linear stages. We fabricated 3D bio devices.
AB - In this paper, we fabricated soft 3D bio devices utilizing PELID (Patterning with Electrostatically-Injected Droplet) method. It is preferable to perform laboratory experiments with 3D structures in bioengineering. We have investigated mechanism and fundamental characteristics of the PELID method and now been applying for new printing technology of high image quality and 3D printing technology. The method has two merits, higher resolution than commercial printer and ability to eject with highly viscous liquid. We can eject viscous paste that viscosity is 30000 mPas. At DF 2010, I already presented that cells and scaffolds were printed to fabricate 3D cell structures because scaffolds assisted the weight of cells. Now, we should fabricate 3D structure that has cave because real 3D structure has blood vessel like cave. It is difficult to fabricate 3D structure that has cave. Gelatin is used as sacrificial layer. When the printed 3D structure is put into hot water, gelatin is removed. With this technique, we can print 3D structure that has cave. The tube filled with the liquid that contained gelatin and the tube filled with the liquid that contained calcium alginate was hanged down perpendicular to a dish. Voltage was applied between the syringes and the dish by power supplies (voltage range: -5kV ∼ +5kV, Matsusada Precision Inc, Tokyo, HVR-10P). The air gap was adjusted by a z-stage and the plate electrode was moved in x and y directions with two linear motors. PC controlled voltage application and motion of linear stages. We fabricated 3D bio devices.
UR - http://www.scopus.com/inward/record.url?scp=84875755031&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=84875755031&partnerID=8YFLogxK
M3 - Conference contribution
AN - SCOPUS:84875755031
SN - 9780892083022
T3 - International Conference on Digital Printing Technologies
SP - 338
EP - 340
BT - NIP 2012
T2 - 28th International Conference on Digital Printing Technologies, NIP 2012 and Digital Fabrication 2012
Y2 - 9 September 2012 through 13 September 2012
ER -